![IBM Power System POWER7 Series Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/ibm/power-system-power7-series/power-system-power7-series_common-service-procedures_3365391043.webp)
Record timer
The time that each event occurs. Depending on the communications hardware that is being used,
the record timer is one of the following values:
1.
A time of day value,
HH:MM:SS.NNNNN
(where
H
=hours,
M
=minutes,
S
=seconds, and
N
=subseconds), based on the system time when the trace was stopped.
2.
A relative time in decimal seconds. This timer value provides the relative time between
events.
Data type
Shows whether the traced data is printed in ASCII or EBCDIC character representation. If the
character representation of the data is mostly periods, you might want to format the data again
using the other option for data representation.
Controller name/number
Indicates which controller originated the frame or record. In some conditions, this data is not
available, and the column remains blank.
Note:
The formatted trace output is not security protected. Customer passwords are shown when they
cross communications lines.
Hexadecimal product activity log data
Use the display hexadecimal report function or follow the steps in this procedure to display hexadecimal
error log dump data.
To display hexadecimal error log dump data, complete these steps:
1.
Find an entry in the product activity log for the system reference code (SRC) you are using to locate
the problem.
a.
Select System Service Tools (SST).
If you cannot get to SST, select DST.
Note:
Do not use an IPL of the system to get to DST.
b.
On the Service Tools display, select the Start a service tool option.
c.
Select the Product activity log option on the Start a Service Tool display.
d.
Select the Analyze log option on the Product Activity Log display.
e.
On the Select Subsystem Data display, select the option to view All Logs.
Note:
If the SRC you are using occurred more than 24 hours ago, change the From and To Dates
and Times from the 24-hour default.
f.
Use the defaults on the Select Analysis Report Options display by pressing the Enter key.
g.
Find the entry in the product activity log that matches that SRC.
2.
Select the Display Detail Report for Resource display. (See the following figures.)
Common service procedures
29
Содержание Power System POWER7 Series
Страница 1: ...Power Systems Common service procedures...
Страница 2: ......
Страница 3: ...Power Systems Common service procedures...
Страница 8: ...vi...
Страница 125: ...Figure 48 Lift up on the EMC shield Common service procedures 111...
Страница 139: ...Figure 60 Lift up on the EMC shield Common service procedures 125...
Страница 186: ...172...
Страница 196: ...182...
Страница 197: ......
Страница 198: ...Printed in USA...