1.
To view all the data associated with the trace, press the Enter key without changing to the defaults on
the Format a Trace Data display . The information is not in any special format.
2.
Select the option to format and print only the data that you want to see.
3.
All options available for formatting depend on the protocol of the line that is being traced. Only valid
choices are shown for each protocol.
4.
Not all combinations of options are valid for all protocols. If you select an option that is not valid,
messages appear. If an error message appears, you must change your selections. Press F5 (Refresh)
function key to restore all options to their default values.
5.
For more information about these options, use online help.
When the format of the trace data is complete, the output can be printed on the console printer (the
printer that is attached to the same I/O processor as the console). Only SCS-type data streams are
supported.
The format of the trace data follows:
v
An introduction page that contains, for example, configuration object, type, protocol, start and stop
dates and times, trace options, and formatting options.
v
A help page, to assist in understanding the output. Help information for a specific protocol is given
because the trace data differs for each communications protocol.
The formatted output is shown as follows.
The width of the file is 132 characters. The data is in hexadecimal representation and either American
National Standard Code for Information Interchange (ASCII) or EBCDIC character representation. The
columns of the trace output that are common to all protocols follows:
Record number
The number of the trace record shows if the record type is sent (S) or received (R).
Notes:
1.
The letter C in this column indicates that an X.21 short-hold mode connection was cleared.
2.
If an M is shown, a modem change occurred.
Data length
The amount of data, in decimal, that the record contains.
Record status
The protocol-dependent return code for the trace record. The value 00000000 is successful; no
errors were found. Other return codes are listed in the functional specification for the protocol
that is running or in the port manager.
Record
Data
Record
Record
Data
Controller
Number
Number
Poll/
Number
S/R
Length
Status
Timer
Type
Name/Number
Command
Sent
Received
Final
------
---
------
--------
---------------
------
-------------
-------
------
--------
-----
7
R
69
00000000
12:29:56.72963
EBCDIC
ZSDLLC30
/01
XID
ON
Data . . . . . :
3245056150080000 0084C00000000000
01010B0000010900 00000007000E0DF4
*.&;...D{....................4*
DADBCC4BDACBCDCE EFCGC5F31017F116
1101130011F9F4F0 F6F5F0F0F1F0F1F0
*ABC.ABCDEFG..1......94065001010*
C4C6C44040
*DFD
*
8
S
0
00000000
12:29:56.76081
EBCDIC
ABCLLC30
/01
SNRM
ON
9
R
0
00000000
12:29:56.78450
EBCDIC
ABCLLC30
/01
UA
ON
52
S
110
00000000
12:29:57.76210
EBCDIC
ABCLLC30
/01
I
0
0
ON
Data . . . . . :
2D00010200006B81 0031001307B0B051
3107878686870706 0200000000000000
*......,A..........GFFG..........*
944300000CDADBCC 4BEAEBCCD3D3C4F3
F02E000902E2D5C1 E2E5C3D4C7090300
*M....ABC.AABCLLD30....SNASVCMG...*
00BCF9CAD600000D 04DADBCC4BEAEBCC
D3D3C4F3F00A1300 7B00BCF9CAD60000
*..9.O....ABC.ABCLLD30...#..9.O..*
000CDADBCC4BEAEB CCD3D3C4F4F0
*..ABC.ABCLLD40
*
53
R
110
00000000
12:29:57.80065
EBCDIC
ABCLLC30
/01
I
0
1
ON
Data . . . . . :
2F00010200006B81 0031001307B0B051
3107878686870706 0200000000000000
*......,A..........GFFG..........*
944300000CDADBCC 4BEAEBCCD3D3C4F4
F02E000902E2D5C1 E2E5C3D4C7090300
*M....ABC.ABCLLD40....SNASVCMG...*
00BCF9D56600000D 04DADBCC4BEAEBCC
D3D3C4F4F00A1300 7B00BCF9D5660000
*..9N.....ABC.ABCLLD40...#..9N...*
000CDADBCC4BEAEB CCD3D3C4F3F0
*..ABC.ABCLLD30
*
* * * * *
E N D
O F
E X A M P L E
P R I N T O U T
* * * * *
Figure 7. Example of formatted trace data output for SDLC
28
Содержание Power System POWER7 Series
Страница 1: ...Power Systems Common service procedures...
Страница 2: ......
Страница 3: ...Power Systems Common service procedures...
Страница 8: ...vi...
Страница 125: ...Figure 48 Lift up on the EMC shield Common service procedures 111...
Страница 139: ...Figure 60 Lift up on the EMC shield Common service procedures 125...
Страница 186: ...172...
Страница 196: ...182...
Страница 197: ......
Страница 198: ...Printed in USA...