High-speed link resources
3.
Press F6 (Print) to print the information.
This ends the procedure.
Hardware service manager
Use the hardware service manager (HSM) to display and work with system hardware.
You can select the hardware service manager option from the Start a Service Tool display. With HSM you
can display and work with system hardware (logical or packaging) and debug input/output processors
(IOP) and devices.
Note:
The system power control network (SPCN) option appears only on systems with SPCN.
The Hardware Service Manager display provides the following information:
v
System type, model, and serial number
v
Licensed Internal Code and operating system release information
v
A list of the hardware service manager options
The options vary depending on the system type and paging environment.
v
Function keys
The function keys vary depending on the display that is shown.
Managing the Advanced System Management Interface
This information describes how to manage the Advanced System Management Interface (ASMI).
The ASMI is the interface to the service processor that is required to perform general and
administrator-level service tasks, such as reading service processor error logs, reading vital product data,
setting up the service processor, and controlling the system power.
The ASMI is sometimes referred to as the service processor menus.
Hardware Service Manager
Attention:
This utility is provided for service representative use only.
System unit . . . . . . . :
9406-570 10-0020A
Release . . . . . . . . . :
V5R3M0
Select one of the following:
1. Packaging hardware resources (systems, frames, cards,...)
2. Logical hardware resources (buses, IOPs, controllers,...)
3. Locate resource by resource name
4. Failed and non-reporting hardware resources
5. System power control network (SPCN)
6. Work with service action log
7. Display label location work sheet
8. Device Concurrent Maintenance
9. Work with resources containing cache battery packs
Bottom
Selection
F3=Exit
F6=Print configuration
F9=Display card gap information
F10=Display resources requiring attention
F12=Cancel
Figure 24. Example of Hardware Service Manager display (in the full and limited paging environments)
Common service procedures
55
Содержание Power System POWER7 Series
Страница 1: ...Power Systems Common service procedures...
Страница 2: ......
Страница 3: ...Power Systems Common service procedures...
Страница 8: ...vi...
Страница 125: ...Figure 48 Lift up on the EMC shield Common service procedures 111...
Страница 139: ...Figure 60 Lift up on the EMC shield Common service procedures 125...
Страница 186: ...172...
Страница 196: ...182...
Страница 197: ......
Страница 198: ...Printed in USA...