¹
For the 6-port V.35/V.36 (FC 2290) adapter, port numbers 0–5
are supported.
4
Make a note of the interface number to which this port is assigned
and the net number.
Repeat steps 1 to 4 if you have a multi-port adapter and you want to
have more than one interface defined on that adapter.
Reboot the IBM 2216 to make the configuration changes active.
Adding an Adapter after Initial Configuration
Question How do I add an adapter after the IBM 2216 has been initially
configured?
Answer
First, perform hardware installation of the adapter. (The section entitled
“2216 FRU Exchange” in the
IBM 2216 Service and Maintenance
Manual describes the removal and replacement procedure. Then:
1
Access the command line interface (
*
prompt).
2
Type talk 6 and press Enter twice to reach the
Config>
prompt.
3
Enter add device
type of device.
For example, add device x21
or, add device ? to see a list of device choices
The following two steps do not apply when a dial-circuit device is
being added.
4
Enter the device slot number (1–8).
5
If you are adding an interface on a single-port adapter, go to step
6. Otherwise, continue with this step. Enter the port number (0–7,
depending on the type of adapter).
The range of port numbers supported depends on the multi-port
adapter type:
¹
For the Token-Ring (FC 2280) and Ethernet (FC 2281)
adapters, port numbers 1 and 2 are supported.
¹
For the 8-port EIA-232E/V.24 (FC 2282) and 8-port X.21
adapters, port numbers 0–7 are supported.
¹
For the 6-port V.35/V.36 (FC 2290) adapter, port numbers 0–5
are supported.
6
Make a note of the interface number to which this port is assigned
and the net number.
7
Enter net
net number to enable you to configure interface-unique
characteristics.
8
Enter exit after configuring the interface.
9
Use the protocol command to configure protocols on the
interface.
10
Enter write to save your changes.
11
Press Ctrl-p to return to the OPCON (*) prompt.
Appendix B. Common Tasks
B-5
Содержание Nways 2216
Страница 1: ...2216 Nways Multiaccess Connector Installation and Initial Configuration Guide GA27 4106 01...
Страница 2: ......
Страница 3: ...2216 Nways Multiaccess Connector Installation and Initial Configuration Guide GA27 4106 01...
Страница 6: ...iv 2216 Installation and Initial Configuration Guide...
Страница 9: ...Common Tasks and the IBM 2216 Library About This Guide vii...
Страница 14: ...xii 2216 Installation and Initial Configuration Guide...
Страница 20: ...1 6 2216 Installation and Initial Configuration Guide...
Страница 24: ...2 4 2216 Installation and Initial Configuration Guide...
Страница 30: ...3 6 2216 Installation and Initial Configuration Guide...
Страница 34: ...4 4 2216 Installation and Initial Configuration Guide...
Страница 48: ...B 12 2216 Installation and Initial Configuration Guide...
Страница 62: ......
Страница 65: ......