IBM® Netfinity® 6000R User’s Reference
1800
A PCI adapter has requested a hardware interrupt that is not available.
Action:
1. Make sure that the PCI adapter and all other adapters are set correctly
in the Configuration/Setup Utility program. If the interrupt resource
settings are not correct, change the settings.
2. If all interrupts are being used by other adapters, you might need to
remove an adapter to make an interrupt available to the PCI adapter,
or force other adapters to share an interrupt.
1962
No valid startup devices were found. The system cannot find the startup drive or
operating system.
Action:
Be sure that the drive you want to start from is in the startup sequence.
1. Select Start Options from the Configuration/Setup Utility program
main menu. If you are unable to set the startup sequence, call for
service.
2. Check the list of startup devices in the Startup device data fields. Is the
drive you want to start from in the startup sequence?
Yes
Exit from this screen; then, select Exit Setup to exit the
Configuration/Setup menu. Go to step 3..
No
Follow the instructions on the screen to add the drive; then,
save the changes and exit the Configuration/Setup menu.
Restart the server.
3. Is an operating system installed?
Yes
Turn off the server. Go to step 4..
No
Install the operating system in your server; then, follow your
operating system instructions to shut down and restart the
server.
4. During server startup, watch for messages indicating a hardware
problem.
If the same error message appears, call for service.
2400
An error occurred during the testing of the video controller on the system board. This
error can be caused by a failing monitor, a failing system board, or a failing video
adapter (if one is installed).
Action:
Verify that the monitor is connected correctly to the video connector. If the
monitor is connected correctly, call for service.
2462
A video memory configuration error occurred.
Action:
Make sure that the monitor cables are correctly and securely connected to
the server.
If the problem persists, call for service.
5962
An IDE CD-ROM configuration error occurred.
Action:
Check the signal and power cable connections to the CD-ROM drive.
If the problem persists, call for service.
POST message
Description
Table 18. POST error messages
Содержание Netfinity 6000R
Страница 1: ...IBM IBM Netfinity 6000R User s Reference SC19 K081 10...
Страница 2: ......
Страница 3: ...IBM IBM Netfinity 6000R User s Reference SC19 K081 10...
Страница 5: ...IBM...
Страница 6: ......
Страница 14: ...xii IBM Netfinity 6000R User s Reference...
Страница 24: ...10 IBM Netfinity 6000R User s Reference...
Страница 36: ...22 IBM Netfinity 6000R User s Reference...
Страница 74: ...60 IBM Netfinity 6000R User s Reference...
Страница 130: ...116 IBM Netfinity 6000R User s Reference...
Страница 198: ...184 IBM Netfinity 6000R User s Reference...
Страница 217: ......