
Note:
See
Chapter
7,
“Parts
listing,
Type
8839,”
on
page
105
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Error
code/symptom
FRU/action
202-XXX-004
(Failed
system
cache
test)
1.
Microprocessor
4
2.
System
board
217-198-XXX
(Could
not
establish
drive
parameters)
SCSI
storage
expansion
unit
217-XXX-000
(Failed
hard
disk
drive
test)
Note:
If
RAID
is
configured,
the
hard
disk
drive
number
refers
to
the
RAID
logical
array.
Hard
disk
drive
1
217-XXX-001
(Failed
hard
disk
test)
Note:
If
RAID
is
configured,
the
hard
disk
number
refers
to
the
RAID
logical
array.
Hard
disk
drive
2
405-XXX-000
(Failed
Ethernet
test
on
controller
on
the
system
board)
1.
Verify
that
Ethernet
is
not
disabled
in
BIOS.
2.
System
board.
Light
path
diagnostics
Lit
blade-error
LED
Cause
Action
None
An
error
has
occurred
and
cannot
be
isolated,
or
the
service
processor
has
failed.
An
error
has
occurred
that
is
not
represented
by
a
Light
Path
Diagnostics
LED.
Check
the
system
error
log
for
more
information
about
the
error.
DIMM
error
A
memory
error
occurred.
1.
Reseat
the
DIMM
indicated
by
the
lit
DIMM
failure
LED.
2.
Replace
the
DIMM.
Note:
Multiple
DIMM
LEDs
do
not
necessarily
indicate
multiple
DIMM
failures.
If
more
than
one
DIMM
LED
is
on,
reseat/replace
one
DIMM
at
a
time
until
error
goes
away.
Refer
to
the
BladeCenter
management
module
system
error
log
for
further
isolation.
Processor
board
fault
The
integrated
VRM
on
the
blade
server
processor
board
has
failed.
1.
Replace
the
blade
server
cover,
reinsert
the
blade
server
in
the
system
chassis,
and
then
restart
the
blade
server.
(See
“Removing
the
blade
server
from
the
BladeCenter
unit”
on
page
39
for
instructions).
2.
Replace
the
processor
board.
I/O
board
fault
The
integrated
VRM
on
the
blade
server
I/O
board
has
failed.
1.
Replace
the
blade
server
cover,
reinsert
the
blade
server
in
the
system
chassis,
and
then
restart
the
blade
server.
(See
“Removing
the
blade
server
from
the
BladeCenter
unit”
on
page
39
for
instructions).
2.
Replace
the
I/O
board.
86
BladeCenter
HS40
Type
8839:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
Содержание HS40 - BladeCenter - 8839
Страница 1: ...BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Страница 2: ......
Страница 3: ...BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Страница 6: ...iv BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 10: ...viii BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 20: ...10 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 30: ...20 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 42: ...32 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 86: ...76 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 114: ...104 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 131: ...Appendix B Safety information 121...
Страница 132: ...122 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 133: ...Appendix B Safety information 123...
Страница 134: ...124 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 135: ...Appendix B Safety information 125...
Страница 136: ...126 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 137: ...Appendix B Safety information 127...
Страница 149: ...Appendix B Safety information 139...
Страница 150: ...140 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 151: ...Appendix B Safety information 141...
Страница 152: ...142 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 153: ...Appendix B Safety information 143...
Страница 154: ...144 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 166: ...156 BladeCenter HS40 Type 8839 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 171: ......
Страница 172: ...Part Number 25K8105 Printed in USA 1P P N 25K8105...