Using
light
path
diagnostics
to
troubleshoot
the
system
board
You
have
to
remove
the
blade
server
from
the
BladeCenter
unit,
open
the
cover,
and
press
the
light
path
diagnostics
switch
(SW4)
to
light
any
error
LEDs
that
were
turned
on
during
processing.
These
LEDs
can
be
used
to
help
troubleshoot
system-board
component
problems.
See
the
illustrations
in
this
section,
and
and
for
information
about
locating
light
path
diagnostics
LEDs
and
what
to
do
if
there
is
an
error
LED
lit.
provides
more
information
about
the
light
path
diagnostics
LED
locations,
settings,
and
error
solutions.
Refer
to
these
illustrations
and
tables
when
solving
problems
with
the
blade
server.
Power
is
available
to
relight
the
light
path
diagnostics
LEDs
for
a
small
period
of
time
after
the
blade
server
is
removed
from
the
BladeCenter
unit.
During
that
period
of
time,
you
can
relight
the
light
path
diagnostics
LEDs
for
a
maximum
of
25
seconds
(or
less,
depending
on
the
number
of
LEDs
that
are
lit
and
the
length
of
time
the
blade
server
is
removed
from
the
BladeCenter
unit)
by
pressing
the
light
path
diagnostics
button.
The
light
path
diagnostics
power
present
LED
(CR111)
is
lit
when
the
light
path
diagnostics
button
is
pressed
if
power
is
available
to
relight
the
blade-error
LEDs.
If
the
light
path
diagnostics
power
present
LED
is
not
lit
when
the
light
path
diagnostics
button
is
pressed,
no
power
is
available
to
light
the
blade-error
LEDs,
and
they
will
be
unable
to
provide
any
diagnostic
information.
The
following
illustration
shows
the
LEDs
on
the
system
board.
Light path diagnostics panel
DIMM 1 error LED
(CR6)
DIMM 2 error LED
(CR5)
DIMM 3 error LED
(CR4)
DIMM 4 error LED
(CR201)
Microprocessor 1 error LED (CR12)
Microprocessor 2 error LED (CR13)
System board fault LED (CR30)
BMC fault LED (CR111)
Table
2.
System
board
LEDs
LED
name
and
location
Description
DIMM
1
error
LED
(CR6)
DIMM
2
error
LED
(CR5)
DIMM
3
error
LED
(CR4)
DIMM
4
error
LED
(CR201)
There
is
a
problem
with
the
corresponding
DIMM.
BMC
fault
(CR11)
There
is
a
problem
with
the
BMC.
Microprocessor
1
error
(CR12)
Microprocessor
2
error
(CR13)
There
is
a
problem
with
the
corresponding
microprocessor.
System
board
fault
(CR30)
There
is
a
problem
with
the
system
board.
16
Eserver
BladeCenter
HS20
Type
8843:
Installation
and
User’s
Guide
Содержание BladeCenter HS20 Type 8843
Страница 3: ...Eserver BladeCenter HS20 Type 8843 Installation and User s Guide ...
Страница 8: ...vi Eserver BladeCenter HS20 Type 8843 Installation and User s Guide ...
Страница 32: ...18 Eserver BladeCenter HS20 Type 8843 Installation and User s Guide ...
Страница 54: ...40 Eserver BladeCenter HS20 Type 8843 Installation and User s Guide ...
Страница 66: ...52 Eserver BladeCenter HS20 Type 8843 Installation and User s Guide ...
Страница 80: ...66 Eserver BladeCenter HS20 Type 8843 Installation and User s Guide ...
Страница 110: ...96 Eserver BladeCenter HS20 Type 8843 Installation and User s Guide ...
Страница 111: ......
Страница 112: ... Part Number 59P4365 Printed in USA 1P P N 59P4365 ...