Note:
See
“System”
on
page
94
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Error
code/symptom
FRU/action
1762
(Hard
disk
configuration
error)
1.
Hard
disk
drive.
2.
Hard
disk
drive
cables.
3.
Run
the
Configuration/Setup
Utility
program.
4.
SCSI
backplane.
5.
System
board.
1962
(Drive
does
not
contain
a
valid
boot
sector)
1.
Verify
that
a
startable
operating
system
is
installed.
2.
Run
diagnostics.
3.
Hard
disk
drive.
4.
SCSI
backplane.
5.
Cable.
6.
System
board.
2462
(Video
memory
configuration
error)
1.
Video
adapter
(if
installed)
2.
System
board
5962
(IDE
CD-ROM
drive
configuration
error)
1.
Run
the
Configuration/Setup
Utility
program.
2.
CD-ROM
drive.
3.
CD-ROM
power
cable.
4.
IDE
cable.
5.
System
board.
6.
Battery.
8603
(Pointing-device
error)
1.
Pointing
device
2.
System
board
0001200
(Machine
check
architecture
error)
1.
Microprocessor
1
2.
Optional
microprocessor
2
3.
System
board
00012000
(Microprocessor
machine
check)
1.
Microprocessor
2.
System
board
I9990650
(AC
power
has
been
restored)
1.
Check
cable.
2.
Check
for
interruption
of
power.
3.
Power
cable.
Service
processor
error
codes
When
viewed
from
POST,
service
processor
(baseboard
management
controller)
error
codes
will
appear
in
hexadecimal
form
(generally
beginning
with
A2,
A3,
A4,
A5,
A6,
A7,
AD,
AE,
or
E1),
unless
a
Remote
Supervisor
Adapter
is
installed.
However,
when
viewed
from
the
System
Error
Log,
the
messages
will
appear
as
text.
To
determine
a
possible
error
condition
for
the
service
processor,
see
the
System
Error
log
(see
“Starting
the
diagnostic
programs
and
viewing
the
test
log”
on
page
18).
ServeRAID
error
codes
In
the
following
error
codes,
x
can
be
any
number
or
letter.
86
Eserver
325
Type
8835:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
Содержание 8835 - Eserver 325 - 1 GB RAM
Страница 1: ...Eserver 325 Type 8835 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Страница 2: ......
Страница 3: ...Eserver 325 Type 8835 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Страница 6: ...iv Eserver 325 Type 8835 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 10: ...viii Eserver 325 Type 8835 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 22: ...12 Eserver 325 Type 8835 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 60: ...50 Eserver 325 Type 8835 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 82: ...72 Eserver 325 Type 8835 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 108: ...98 Eserver 325 Type 8835 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 123: ...Appendix B Related service information 113...
Страница 124: ...114 Eserver 325 Type 8835 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 125: ...Appendix B Related service information 115...
Страница 126: ...116 Eserver 325 Type 8835 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 127: ...Appendix B Related service information 117...
Страница 128: ...118 Eserver 325 Type 8835 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 129: ...Appendix B Related service information 119...
Страница 142: ...132 Eserver 325 Type 8835 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 143: ...Appendix B Related service information 133...
Страница 144: ...134 Eserver 325 Type 8835 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 145: ...Appendix B Related service information 135...
Страница 146: ...136 Eserver 325 Type 8835 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 147: ...Appendix B Related service information 137...
Страница 152: ...142 Eserver 325 Type 8835 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 158: ...148 Eserver 325 Type 8835 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 163: ......
Страница 164: ...Part Number 90P3053 Printed in USA 1P P N 90P3053...