v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
the
parts
listing
in
the
Problem
Determination
and
Service
Guide
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
LED
Description
Action
SP
The
service
processor
has
failed.
Attention:
In
a
dc
power
environment,
only
trained
service
personnel
other
than
IBM
service
technicians
are
authorized
to
connect
or
disconnect
power
to
the
dc
power
supply.
See
the
documentation
that
comes
with
each
dc
power
supply.
1.
Remove
power
from
the
server;
then,
reconnect
the
server
to
power
and
restart
the
server.
2.
Update
the
firmware
on
the
BMC.
3.
If
a
Remote
Supervisor
Adapter
II
SlimLine
is
installed,
update
the
firmware;
if
the
problem
remains,
replace
the
Remote
Supervisor
Adapter
II
SlimLine.
4.
Call
for
service
DASD
A
hard
disk
drive
error
has
occurred.
1.
Check
the
LEDs
on
the
hard
disk
drives
and
replace
the
indicated
drive.
2.
Call
for
service.
RAID
A
RAID
controller
error
has
occurred.
1.
Make
sure
that
a
RAID
controller
is
installed.
Note:
The
server
will
not
start
without
a
RAID
controller
installed.
2.
Check
the
system-error
log
for
information
about
the
error.
FAN
A
fan
has
failed,
is
operating
too
slowly,
or
has
been
removed.
The
TEMP
LED
might
also
be
lit.
Replace
the
failing
fan,
which
is
indicated
by
a
lit
LED
on
the
fan
itself.
TEMP
The
system
temperature
has
exceeded
a
threshold
level.
A
failing
fan
can
cause
the
TEMP
LED
to
be
lit.
1.
Determine
whether
a
fan
has
failed.
If
it
has,
replace
it.
2.
Make
sure
that
the
room
temperature
is
not
too
high.
See
“Features
and
specifications”
on
page
3
for
temperature
information.
3.
Make
sure
that
the
air
vents
are
not
blocked.
4.
Call
for
service.
BRD
An
error
has
occurred
on
the
system
board.
1.
Check
the
LEDs
on
the
system
board
to
identify
the
component
that
is
causing
the
error.
2.
Check
the
system-error
log
for
information
about
the
error.
PCI
An
error
has
occurred
on
a
PCI
bus
or
on
the
system
board.
An
additional
LED
will
be
lit
next
to
a
failing
PCI
slot.
1.
Check
the
LEDs
on
the
PCI
slots
to
identify
the
component
that
is
causing
the
error.
2.
Check
the
system-error
log
for
information
about
the
error.
3.
If
you
cannot
isolate
the
failing
adapter
through
the
LEDs
and
the
information
in
the
system-error
log,
remove
one
adapter
at
a
time
from
the
failing
PCI
bus,
and
restart
the
server
after
each
adapter
is
removed.
4.
Call
for
service.
Chapter
2.
Installing
optional
devices
27
Содержание 7979B1U
Страница 1: ...System x3650 Type 7979 User s Guide...
Страница 2: ......
Страница 3: ...System x3650 Type 7979 User s Guide...
Страница 8: ...vi System x3650 Type 7979 User s Guide...
Страница 30: ...14 System x3650 Type 7979 User s Guide...
Страница 130: ...114 System x3650 Type 7979 User s Guide...
Страница 138: ...122 System x3650 Type 7979 User s Guide...
Страница 143: ......
Страница 144: ...Part Number 44R5189 Printed in USA 1P P N 44R5189...