Tower model
Dimensions
Height: 492 mm (19.4 in.)
Width: 200 mm (7.9 in.)
Depth: 445 mm (17.5 in.)
Weight
Minimum configuration as shipped: 15 kg (33
lb)
Maximum configuration: 17.3 kg (38 lb)
Environment
Air temperature:
– System on: 10° to 32°C (50° to 90°F)
– System off: 10° to 43°C (50° to 110°F)
Humidity:
– System on: 8% to 80%
– System off: 8% to 80%
Maximum altitude: 2134 m (7000 ft)
Electrical input
Sine-wave input (50 to 60 Hz) is required
Input voltage:
– Low range:
- Minimum: 90 V ac
- Maximum: 137 V ac
- Voltage switch setting: 115 or 115 V
– High range:
- Minimum: 180 V ac
- Maximum: 265 V ac
- Voltage switch setting: 230 or 230 V
– Input kilovolt-amperes (kVA)
(approximately):
- Minimum configuration as shipped:
0.08 kVA
- Maximum configuration: 0.51 kVA
Note:
Power consumption and heat output
vary depending on the number and
type of optional features installed and
the power management optional
features in use.
Heat output
Approximate heat output in British thermal
units (Btu) per hour:
– Minimum configuration: 245 Btu/hr (70
watts)
– Maximum configuration: 969 Btu/hr (285
watts)
Airflow
Approximately 0.56 cubic meters per minute
(20 cubic feet per minute)
Acoustical noise-emission values
Average sound-pressure levels:
– At operator position:
- Idle: PC 300PL - 33 dBA
PC 300GL - 36 dBA
- Operating: PC 300PL - 35 dBA
PC 300GL - 37 dBA
– At bystander position–1 meter (3.3 ft):
- Idle: PC 300PL - 29 dBA
PC 300GL - 30 dBA
- Operating: PC 300PL - 32 dBA
PC 300GL - 33 dBA
– Declared (upper limit) sound power
levels:
- Idle: PC 300PL - 4.5 bels
PC 300GL - 4.7 bels
- Operating: PC 300PL - 4.8 bels
PC 300GL - 4.9 bels
Note:
These levels were measured in
controlled acoustical environments according
to procedures specified by the American
National Standards Institute (ANSI) S12.10
and ISO 7779, and are reported in accordance
with ISO 9296. Actual sound-pressure levels
in your location might exceed the average
values stated because of room reflections and
other nearby noise sources. The declared
sound power levels indicate an upper limit,
below which a large number of computers
will operate.
Chapter 1. Your IBM personal computer
19
Содержание 6862 - PC 300 PL
Страница 2: ......
Страница 10: ...viii Using Your Personal Computer...
Страница 14: ...xii Using Your Personal Computer...
Страница 18: ...xvi Using Your Personal Computer...
Страница 38: ...20 Using Your Personal Computer...
Страница 78: ...60 Using Your Personal Computer...
Страница 116: ...98 Using Your Personal Computer...
Страница 158: ...140 Using Your Personal Computer...
Страница 207: ......
Страница 208: ...IBM Part Number 00N5979 Printed in U S A N5979...