Wiring Terminals for Type 1503, 1513
Terminal
Function
1
+ 24 V DC
2
Ground 24 VDC
3
Accelerometer 1 Signal
4
Accelerometer 1 Ground
5
Alarm A
6
Alarm B
7
Alarm C
8
Alarms Set Input (Set 1)
9
Machine Speed Input (1 pulse per rev)
10
+24 V DC Supply for alarm outputs
11
Ground alarms
12
Option Analog Out 0 – 10 Volt for mm/s for input 1
13
Option Analog Out 0 – 10 Volt for gSE for input 1
14
Ground for analog outputs)
15
Ground for analog outputs
16 (1
st
upper
row)
Option Analog Out 0 – 10 Volt for mm/s for input 2
17
Option Analog Out 0 – 10 Volt for gSE for input 2
18
Option Analog Out 0 – 10 Volt for mm/s for input 3
19
Option Analog Out 0 – 10 Volt for gSE for input 3
20
Accelerometer 2 Signal
21
Accelerometer 2 Ground
22
Accelerometer 3 Signal
23
Accelerometer 3 Ground
24
DIG IN 1 (digital input 1) / Event enable
25
DIG IN 2 (elapsed hour counter)
26
DIG IN 3 (tool change counter)
27
DIG IN 4 (store)
28
DIG GND
29
CAN Ser + (Option)
30
CAN Ser – (Option)
For further descriptions see above