Basic Software Configuration
Software Language and Data Path
Communication
Select the language from the dropdown
list box. Store the changes, quit and
reopen the software to make changes
active.
The standard data path is:
C:Record_Control\Dat
You can use any other folder
accessible by your PC, also i fit is
physically located on a server. Copy
the files from the standard path to the
required one and change the setting
Choose the bus system first:
RS232
Choose the COM port to use with a serial
null modem (cross over) cable for
communication betreen instrument and PC.
The baudrate ist 19200 baud.
Attention:
If you are using one of the
proigrams from the utility CD of the card
reader, make sure you close it before
openning Record Control.
The following options are only available in
record Control Net:
CAN-Bus NI-CAN and P-CAN
For CAN-Bus adapters from National
Instruments or Peak Elektronik
Each instrument must have a properly set
CAN adress. All nodes on the bus must be
set to use the same baudrate.
Ethernet
For SiViB Records with Ethernet port.
Ethernet-CAN Gateway
For a cluster of SiViB Instruments and a
Gateway module talking to the PC via
Ethernet.
Multibus
For multiple monitors with Ethernet
connector