11
7. Connection With the Controller
7-1 Connection with the Teaching Pendant
(1) Connect the Teaching Pendant Cable to the “PORT IN” connector which is located on the front of the
controller.
Always turn the PORT switch OFF first before connecting a controller having this switch.
For the locations of the main communication “Port IN” connector and PORT switch, refer to the
operating manual for the controller you use.
(2) After connecting, turn the PORT switch of the controller having this switch ON.
(If the Deadman SW is attached as an option, execute while the Deadman SW button on both sides
are pressed.)
7-2 How to Disengage the Teaching Pendant
Hold down the BEGlN/END key which is located in the upper left corner of the key pad. Select "*
Complete" to finish.
Then, turn the PORT switch OFF for the controller having this switch.
Operation:
1. Hold down the
key for more than 2.5 seconds.
2. Use the Arrow key to select “* Complete” Screen, and then press the Return key.
3. Turn the PORT switch OFF for the controller having this switch.
4. Remove the Teaching Pendant connector.
Caution:
In the case of PCON, ACON, SCON, or ERC2, an instantaneous stop will be made when
the Teaching Pendant is disconnected. However, this is not an error.
Caution:
In the case of the PCON, ACON, or ERC2 controller not having the AUTO/MANU switch,
set the TP Operation Mode to “Monitor 2” before disconnecting the Teaching Pendant from
the controller. (Refer to “8.10 TP Operation Mode.”)
In the case of ERC2 or when controller setting is made by connecting the Teaching Pendant
to the gateway unit or SIO converter:
●
If the Teaching Pendant is disconnected while the setting of “Teach 1” or “Teach 2”
remains, I/O will become invalid and control from PLC will become impossible.
●
If the Teaching Pendant is disconnected while the setting of “Monitor 1” remains, the
maximum speed will become the safety speed set for the parameter regardless of a
command from PLC.
Содержание RCM-TD
Страница 1: ...Teaching Pendant Operating Manual First edition IAI America Inc...
Страница 2: ......
Страница 4: ......
Страница 6: ...MEMO...
Страница 14: ...6 6 2 External View External Dimensions When drawing out the manual card...
Страница 82: ...74 Pulse Position Display PCON PL PO ACON PL PO SCON Pulse Train Mode Current Value mA Display 1 6 5...
Страница 86: ...78 Examples of PCON CY Controller...
Страница 105: ......