72
Configure the settings and operations relating to the system
[System management]
The settings relating to the actions at an error occurrence and auto data deletion from hard disk drives can be
configured on this tab. It is also possible to display the logs on this page. In addition, general maintenance,
such as license registration, setting initialization and firmware upgrade, can be performed on this tab.
■
System setup
[Error output duration]
Select the duration to output a signal to notify the
external devices of an error (HDD error, camera error,
recorder error, recording error or network error).
When "0 s" is selected, the signal is not output.
0 s/ 2 s/ 5 s/ 10 s/ 20 s/ 30 s/ 1 min
Ext.: When "Ext." is selected, the signal will keep
on being output until the error is reset.
Default:
2 s
Note:
• Refer to the "Cancel the error action" section
(
☞
Page 125) for how to reset the error.
[Error buzzer duration]
Configure the settings to sound a buzzer at an error
occurrence. When "0 s" is selected, buzzer will not
sound.
0 s/ 2 s/ 5 s/ 10 s/ 20 s/ 30 s/ 1 min
Ext.: When "Ext." is selected, the buzzer that
started sounding at an error occurrence will
keep on sounding until the buzzer is stopped.
Default:
2 s
Note:
• Refer to the "Stop buzzer beeping" (
☞
for further information about how to stop buzzer
beeping.
[HDD hour meter warning]
If the operation time of a hard disk drive reaches a
specified level, a warning will be performed. When
"Off" is selected, warning will not be performed.
Off/ 10000 h/ 20000 h/ 30000 h/ 40000 h/ 50000 h
Default:
20000 h
[Auto data delete]
Select to determine how many days should have
passed from the recorded day to delete data
automatically from the hard disk drive.
Off/ 1 day/ 2 days/ 3 days/ 4 days/ 5 days/ 6 days/
7 days/ 8 days/ 9 days/ 10 days/ 14 days/ 30 days/
45 days/ 60 days/ 90 days/ 120 days/ 150 days/
180 days/ 184 days/ 365 days/ 366 days/ 730 days/
731 days
Default:
Off (Does not delete the data automatically.)
[Camera time auto synchronization]
When a date changes, the clock of the cameras will
be synchronized with the clock of this product.
On: Synchronized
Off: Not synchronized
Default:
On
[General purpose I/O terminal setting]
[General purpose 1] [General purpose 2]
Sets the application of the General purpose input/
output terminals.
If the General purpose I/O terminals are not used, set
to "Undefined".
Undefined/Alarm input/Alarm reset input/Network
error output/Recorder error output
Default setting: Undefined
[Setup via recorder's main monitor]