ISH & ISHV & ISHVS CONNECTOR Instruction Manual
Document No.
HDM-0002
5
/
29
Confidential C
3-3. Terminal part names
3-4. Crimping requirements
(1) Crimp dimension
Crimped female terminals must satisfy the crimp dimension specified in Table 1.
※
Crimp dimensions may be different depending on conductor construction of the wire.
Please contact our Sales Department shown in 15(sheet 29) about wire used, then we will verify it and
notify you the appropriate crimp dimensions.
Fig 3. Terminal part names
Table 1. Crimp dimension
0.5mm
2
0.95±0.05 (
※
)
1.8±0.05
Wire barrel Crimp Width
Insulation barrel Crimp Height
Insulation barrel Crimp Width
VT001-512
VT001-552
0.3mm
2
Φ1.60mm MAX.
0.9±0.05 (
※
)
1.4±0.04
1.6+0.1/-0.05
1.55±0.05
Part No.
Wire Size
Insulation
Outer Diameter
Wire barrel Crimp Height