ISH & ISHV & ISHVS CONNECTOR Instruction Manual
Document No.
HDM-0002
8
/
29
Confidential C
(2) Bottom burrs
Burrs produced during crimping process must not extend beyond the bottom surface. (see Fig.9)
(3) Bellmouth,excess conductors and cut-off tab
Bellmouth,excess conductors and cut-off tab must satisfy the dimensions shown in Fig. 10.
No
ext
ens
ion
Extension
Bottom surface of terminal
Bottom burrs
【Good】
【No good】
Fig 9. Bottom burrs
Fig.10. Bellmouth, excess conductors and cut-off tab