ISH & ISHV & ISHVS CONNECTOR Instruction Manual
Document No.
HDM-0002
4
/
29
Confidential C
3. Crimping procedure
3-1. Applicable wires
3-2. Wire strip length
①
Strip the insulation off by 3.0±0.1mm (see Fig.1)
②
Check to see that there is no damage to the conductors or insulation, cut off conductors, short conductors
and deformed conductors as shown in Fig. 2.
Do not use wires with damaged conductors, cut off conductors, short conductors and deformed conductors.
Using faulty wires may cause crimping problems.
Part No.
Applicable Wire
VT001-512
VT001-552
wire size
:
0.3mm
2
・
0.5mm
2
Insulation outer diameter
:
Φ
1.60mm MAX.
Cut off conductors
(defect)
Deformed conductors
(defect)
Condition
Image
Good
Damaged conductors
(defect)
Fig 1.Wire strip
Fig 2. Stripped wires (unacceptable examples)
3.0±0.1mm
Conductors
Insulation