Maintenance and RepaiR
powermax
65/85
Operator Manual
5-7
Fault
code
Description
Power
LED
Fault
LED
Fault
icon
Solutions
0-21
Gas flow lost while
cutting
On
On
• Restore the gas inlet pressure and restart the power
supply.
• Check the torch lead for leaks or kinking.
0-22
No gas input
On
On
• Connect the gas source and restart the power
supply.
0-30
Torch consumables stuck
This indicates either a
“torch stuck open” or
a “torch stuck closed”
situation.
On
On
• If the consumables became loose or were removed
while the power supply is ON, turn OFF the power
supply, correct the problem and then turn ON the
power supply to clear this fault.
• If the consumables appear to be installed
correctly, the torch may be damaged. Contact your
Hypertherm distributor or authorized repair facility.
0-40
Over/under temperature
On
On
• Leave the power supply on to allow the fan to cool
the power supply.
• If the internal temperature of the power supply
approaches -22° F (-30° C), move the power supply
to a warmer location.