Torch SeTup
3-18
powermax
65/85
Operator Manual
Note: The cover on the machine interface receptacle prevents dust and moisture from damaging the receptacle
when not in use. This cover should be replaced if damaged or lost (part number 127204).
See the
Parts
section for more information.
Installation of the machine interface cable must be performed by a qualified service technician. To install a machine
interface cable:
1. Turn OFF the power and disconnect the power cord.
2. Remove the machine interface receptacle’s cover from the rear of the power supply.
3. Connect the Hypertherm machine interface cable to the power supply.
4. If you are using a cable with a D-sub connector on the other end, plug it into the appropriate pin connector on the
torch height controller or CNC. Secure it with the screws on the D-sub connector.
If you are using a cable with wires and spade connectors on the other end, terminate the machine interface
cable inside the electrical enclosure of listed and certified torch height controllers or CNC controllers to prevent
unauthorized access to the connections after installation. Verify that the connections are correct and that all live
parts are enclosed and protected before operating the equipment.
Note: The integration of Hypertherm equipment and customer-supplied equipment including interconnecting cords
and cables, if not listed and certified as a system, is subject to inspection by local authorities at the final
installation site.
The connector sockets for each type of signal available through the machine interface cable are shown in the figure
below. The table provides details about each signal type.
Содержание powermax65
Страница 1: ...Plasma arc cutting systems Operator Manual 806650 Revision 2 ...
Страница 10: ...vi powermax65 85 Operator Manual ...
Страница 14: ...Table of Contents x powermax65 85 Operator Manual ...
Страница 30: ...Specifications 1 16 powermax65 85 Operator Manual ...
Страница 150: ...Parts 6 16 powermax65 85 Operator Manual ...