Problem
Solutions
The arc blows out, but re-ignites when
the torch trigger is pressed again.
• Inspect the consumable parts and replace them if they are worn or
damaged. See 5-3
Inspect the consumables
.
• Replace the gas filter’s element if it is contaminated. See 5-10
Replace
the gas filter element
.
• Make sure the gas pressure is at the proper level.
The arc sputters and hisses.
• The gas filter’s element is contaminated. Replace the element. See 5-10
Replace the gas filter element
.
• Inspect the gas line for moisture.
If necessary, install or repair the gas
filtration to the power supply. See Section 2,
Power Supply Setup,
for
more information..
The cut quality is poor.
• Verify that the torch is being used correctly. See Section 4,
Operation.
• Inspect the consumables for wear and replace as necessary. See 5-3
Inspect the consumables
.
• Check the air pressure and air quality.
• Verify that the cutting mode switch is in the proper position for the cutting
operation.
• Verify that the correct consumables are installed.