SPA
Page 63
9.
For the Installer
9.1
Temperature Sensor Installation
With steam baths, a temperature sensor must be installed in the cabin.
The sensor measures the active temperature and sends the value to
the control. The recorded temperature constitutes a control variable for
controlling steam production.
Please note:
•
Do not install the sensor close to the steam manifold.
•
Mount the sensor on the wall and not in or under the wall panel-
ing.
The best installation location for the temperature sensor is 800 - 1000
mm above the bench surface (about the head height of the steam
bather).
Risk of scalding due to high steam temperature effected by tem-
perature sensor manipulation!
Do not cover the temperature sensor or douse with water.
9.2
Temperature Sensor Connection
Connect the temperature sensor cable to the designated terminals 6
and 7 on the HygroMatik steam generator.
Test using the table below. While the sensor has been calibrated in the
factory, subsequent adjustment within a range of -5K to +5K is possible
using a 2nd temperature gauge.
Temperature Resistance Table
Temperature [°C]
Resistance [kOhm]
10
28,5
20
18,5
30
12,3
40
8,3
50
5,8
60
4,1
70
2,9
80
2,1
Please note