SPA
Page 34
E7
2. Transmitting relay
same options as with E5, sta-
tus 14 = factory setting
Parameter Setting / Data
Parameters
010
E8
3. Transmitting relay
same options as with E5, sta-
tus 13 = factory setting
Parameter Setting / Data
Parameters
010
E9
4. Transmitting relay
same options as with E5, sta-
tus 16 = factory setting
Parameter Setting / Data
Parameters
010
E17
Baud rate (interface)
9600 / 4800 / 2400 / 1200
Parameter Setting / Data
Parameters
010
G0
Calibration °C actual
value
-5 to 5 K
Parameter Settings/
Steam Bath Parameters
010
G1
Hysteresis controller
0 - 10 K
1 K = Factory Setting
Parameter Settings/
Steam Bath Parameters
010
G2
Steam Bath °C set Value 0 - 49 °C
45 °C = Factory Setting
Parameter Settings/
Steam Bath Parameters
010
G3
Hysteresis exhaust fan
0 - 10 K
1 K = Factory Setting
Parameter Settings/
Steam Bath Parameters
010
G4
Time essence injection
0 - 25 sec.
2 sec. = Factory Setting
Parameter Settings/
Steam Bath Parameters
010
G5
Interval time essence
injection
0 - 99 min.
5 min. = Factory Setting
Parameter Settings/
Steam Bath Parameters
010
G6
Hysteresis essence
injection
0 -25 K
25 K = Factory Setting
Parameter Settings/
Steam Bath Parameters
010
G7
Hysteresis °C max.
0 -25 K
10 K = Factory Setting
Parameter Settings/
Steam Bath Parameters
010
G8
Fan run-on time
0 - 999 min.
0 min. = Factory Setting
Parameter Settings/
Steam Bath Parameters
010
G9
Power retention
0 - 100 %
0 % = Factory Setting
Parameter Settings/
Steam Bath Parameters
010
G13
Hysteresis supply fan
0 - 10 K
1 K = Factory Setting
Parameter Settings/
Steam Bath Parameters
010
H1
Counter Partial Blow-
down
0 - 255 [Filling Cycle]
Parameter Setting/Blow-
Down Parameters
010
H2
Time Partial Blow-down) 0-255 [s]
Parameter Setting/Blow-
Down Parameters
010
H6
Full Blow-Down
Yes (On)
No (Off)
Parameter Setting/Blow-
Down Parameters
010
H11
CounterPartial Blow-
down
0 - 999 kg
Parameter Setting/Blow-
Down Parameters
010
H12
TimePartial Blow-down
0-255 [s]
Parameter Setting/Blow-
Down Parameters
010
P1
Output limitation
25% - 100%
Parameter Setting/
Conrol Parameters
none
P2
Maintenance interval
0,1 - 25,5 [10³ kg]
Parameter Setting/Mainte-
nance Parameters
010
P3
Reset maintenance
interval
Yes / No
Parameter Setting/Mainte-
nance Parameters
010
P5
Address
1 - 999
Parameter Setting/ Data
Parameters
none
P11
Reset main contactor
interval
Yes / No
Parameter Settings/Main-
tenance Parameters
010
Para-
meter
Designation
Possible Settings
in Menu / Submenu
Access
Code