SPA
Page 39
Modifying set Temperature Value (G2)
Note:
The temperature may be modified in increments of 1°K in the
main menu.
Example:
The desired temperature value should be reduced from 45
°C to 42 °C.
To do this, proceed as follows:
»
press
in Operating Mode
»
select “Parameter Settings” menu with
or
»
enter the “Parameter Settings” menu with
»
the access code (P0=010) to the advanced customer level
must be entered; press
»
press
»
press
»
select the “Steam Bath Parameters” submenu with
or
»
enter the “Steam Bath Parameters” submenu with
»
select Parameter G2 “Steam Bath °C Set Value” with
or
»
enable Parameter G2 with
»
press
twice to move the cursor under the third digit
»
»
press
three times to reduce the value from 5 to 2
Sprache / Language
ESC
Parameter Settings
ESC
Code 000
ESC
Code 000
ESC
Code 010
ESC
Maintenance
Parameters
ESC
Steam Bath
Parameters
ESC
Steam Bath Mode
D0: without Status
ESC
Steam Bath
°C Set Value
G2: 45 °C
ESC
Steam Bath
°C Set Value
G2: 045 °C
ESC
Steam Bath
°C Set Value
G2: 045 °C
ESC