14
TROUBLE SHOOTING GUIDE
AQUAFIER
®
FILTRATION SYSTEM
Symptom
Probable Cause
Solution
No water.
Water supply is turned OFF.
Turn water ON.
Not enough water.
Water supply is blocked.
Clogged filter cartridges are restricting water
flow.
Clear restriction, rotate valve handle on tap
water feed valve.
Replace filter cartridges.
Water has an offensive taste and/or odor.
Filters depleted.
Replace filters, clean and sanitize system.
Leak at fitting.
Tubing not pushed completely into fitting.
Defective tube.
Worn or damaged "O" Ring.
Push tube into fitting past "O" Ring seal.
Cut damaged area off of tube or replace tube.
(refer to Page 1, Figure 2)
Replace "O" Ring*.
Leak at filter housing.
"O" Ring has not seated.
"O" Ring has nick or scratches.
Lube and Reseat "O" Ring*.
Replace "O" Ring *.
Leak at saddle tapping valve.
Loose clamp.
Tubing deformed.
Tighten clamp screws, do not crush source
water tubing.
Cut damaged area off of tube or replace tube
and sleeve.
* Always check there is adequate lubricant (P/N 30300026) on "O" Rings before installation.
OPTIONAL SMARTAP
®
WATER FLOW MONITOR
Symptom
Probable Cause
Solution
Yellow Service Light.
Filters depleted.
Battery not replaced when filters changed.
Replace filters.
Replace battery.
No Lights.
Light assembly is not connected.
Plug connector into phone jack.
CAUTION:
Change the battery only when changing the filters as removal and replacement of the battery resets the Aquafier
®
monitor.
CAUTION:
Change the battery each time the filters are changed. If battery is not replaced, user/technician cannot determine system status within
cycle.
Table 2
System Troubleshooting Indicators, Common Solutions, and Correction Procedures