background image

 
 
 

12 

CLEANING, SANITIZING, AND CARTRIDGE REPLACEMENT PROCEDURE

 

 

1.  Mix a mild cleaning solution of dish soap and clean 

potable water in the plastic bowl. 

 
2.  Shut feed water supply valve and open product water 

faucet to relieve system pressure. 

 

NOTE:

  Do not attempt to remove filter housings until water 

flow stops.  This reduces pressure inside the 
system so housings may be safely removed. 

 
3.  Remove each filter housing by turning it counter-

clockwise. Remove each filter cartridge as its housing 
is removed.  Discard filters. 

 

Icemaker:

 Transfer ice cubes from bin/tray to clean 

freezer container for storage until procedure is done. 

 

NOTE:

  Use sanitary rubber gloves for this procedure to 

avoid contaminating sanitizing solution or filters.  
Wear gloves whenever cleaning/ sanitizing system 
components or handling new filter cartridges. 

 
4.  Remove filter housing "O" rings and wash them with 

cleaning solution.  Rinse them well with clean potable 
water. Inspect the "O" rings for damage (i.e., nicks or 
scratches).  Replace damaged "O" rings.  

 

NOTE:

  Use caution when cleaning module.  Do not get the 

Smartap

®

 Flow Monitor electronics, wiring, or 

connectors wet. 

 
5.  Clean filter housings and manifold ports, inside and 

outside with washcloth and cleaning solution.  Do not 
use abrasive materials.   

 
6.  Rinse housings/manifold with clean potable water.  
 
7.   Inspect manifold and filter housing "O" ring groove 

area for damage (i.e., nicks or scratches).  Replace 
damaged components. 

 
8.  Place a small amount of "O" ring lubricant over the 

surface of the filter housing "O" ring. Install the "O" ring 
into the filter housing groove. 

 

TO SANITIZE SYSTEM: 

Complete Steps 9-29. 

TO INSTALL FILTERS:  

Complete Steps 17-29. 

 

CAUTION:

  WEAR SAFETY GLASSES WHILE 

PERFORMING THIS PROCEDURE. 

 

CAUTION: 

EXCESSIVE CONCENTRATIONS OF 

 

 

 

BLEACH WILL DAMAGE PLASTIC AND  

 

 

 

RUBBER COMPONENTS.  Rinse all parts 

 

 

 

that contact bleach thoroughly with clean  

   potable 

water. 

CAUTION:

  Read the "WARNINGS" on the bleach 

container before using. 

 

CAUTION:

  Handle sanitizing solution carefully.  Avoid 

contact with unprotected areas. 

 
9.  Mix sanitizing solution of 1.5 ml (1/3 teaspoon) of 

household bleach and 3.8 L (1 gallon) of clean, potable 
water in the bucket.  Mix the solution well. 

 
10.  Add 236 ml (one cup or 8 oz.) of sanitizing solution to 

each of the filter housings and install them onto the 
manifold (do not install filters at this time).  Tighten 
each filter housing by hand only. 

 

NOTE:

  TIGHTEN FILTER HOUSINGS BY HAND 

ONLY.  Do not use tools as they will over-
tighten and damage housings. 

 
11.  Slowly open the feed water supply valve.   
 
12.  Open product water faucet.  Keep open for 5 seconds 

after water starts coming out.  

 
13.  Close the product water faucet.  
 
14.  Wait 30 minutes, open product water faucet and let  

water flow 5 minutes. 

 
15.  After 5 minutes, close feed water supply valve and 

allow water to flow until system pressure is relieved. 

 

NOTE:

  Do not attempt to remove filter housings until water 

flow stops.  This reduces pressure inside the 
system so housings may be safely removed. 

 
16.  Remove the filter housings and dispose of the water.  

Rinse housings and manifold ports thoroughly with 
clean potable water. 

 

NOTE:

  Do not remove protective plastic bag from filters.  

Open the top of the bag only enough to expose the 
top cap and "O" rings.  Place a small amount of 
“O” ring lubricant on surface of each “O” ring. 

 
17.  Install the filter cartridges.  Hold cartridge by its 

protective plastic bag and insert the cartridge into the 
manifold turning it 1/2 turn as it enters the port (See 
Page II, Figure 1 for location of each cartridge).   

 

Slide bag from cartridge and discard.  Replace each 
filter housing as each cartridge is installed. 

 

NOTE:

  TIGHTEN FILTER HOUSINGS BY HAND 

ONLY.  Do not use tools as they will over-
tighten and damage housings. 

Содержание 10401

Страница 1: ...OWNER S GUIDE NSFR AQUAFIER ADVANCED ACTIVATED CARBON WATER TREATMENT SYSTEM Model Series 10401 10402 10403 Hydrotech Inc 25555 West Avenue Stanford Valencia CA 91355 661 294 8888 FAX 661 294 8880...

Страница 2: ...OR The optional Smartap Monitor indicates filter cartridge status by measuring the volume of water passing through the Aquafier Water Treatment System When water is dispensed it flows through the syst...

Страница 3: ...Quality Monitor Pushbutton Smartap Water Quality Monitor Module Only No Monitor Product Water Faucet Chrome or Stainless Steel Polymer Plain Front or with Light Bar Page I Table A Page 7 Fig 7 Page 9...

Страница 4: ...are access to cold water supply line and to household sink Specific requirements are detailed in Table 1 PRODUCT WATER FAUCET FILTRATION MODULE Faucet may be installed in any convenient location Make...

Страница 5: ...cause the tubing to flex and deform which reduces its flow capacity and may increase lateral stress on the fittings causing leaks QUICK CONNECT FITTINGS Fittings consist of two parts a Body and a colo...

Страница 6: ...side projections 1 2 or larger tubing use V side of bracket See Figure 3B b Hold Valve Saddle against tubing in a position directly opposite Back Plate c Install screws far enough so Saddle and Back...

Страница 7: ...nst pipe e Tighten screws evenly brackets must be parallel Tighten each screw firmly Do not crush pipe 4 Connect source water tubing to valve housing using compression fitting See Page 2 Step 4 5 Conn...

Страница 8: ...6 7 and 8 EXISTING COLD WATER SUPPLY VALVE COLD WATER LINE TO SINK 4 Insert rubber washer Item 1 into inlet adapter Item 2 and install adapter onto supply valve Align outlet hole in side of adapter t...

Страница 9: ...htly Insert pilot guide into pilot hole Push down gently on drill motor to apply light pressure to porcelain surface Start drill motor turning as slowly as possible After initial cut has started motor...

Страница 10: ...e washer are in place above sink Items 2 3 and 4 Optional Faucet Smartap Verify faucet body metal faucet base washer light bar base washer light bar assembly and washboard gasket are in place above si...

Страница 11: ...Handle Faucet Body Faucet Stainless Steel Washer Faucet Base Stainless Steel Washer Rubber Faucet Base Washer Slotted Washer Faucet Nut Faucet Connector Faucet 3 8 x 7 16 Kit Rebuild Faucet Stainless...

Страница 12: ...g nut by hand so that faucet does not move Do not over tighten NOTE Faucet is packaged for right hand operation For left hand operation realign knob by completing Step 5 NOTE Item callouts in Step 5 r...

Страница 13: ...designates faucet body with plain front Code 1 designates faucet body with 1 LED Code 2 designates faucet body with 2 LED Code 3 designates faucet body with 3 LED Example 40303935 is a Faucet Body Ass...

Страница 14: ...lel Cross over O Ring Port Retainer Plug Port Retainer Plug Switch Housing O Ring Switch Housing Plug O Ring Cartridge Activator Smartap Flow Monitor Sending Unit Flow Switch Spring Flow Switch Magnet...

Страница 15: ...Gap Faucet Part Number Stainless Steel Faucet Only Stainless Steel with Light Bar 40301007 11702002 Chrome Faucet Only Chrome with Light Bar 40301002 11702001 Polymer Plain Front Polymer Light Bar 114...

Страница 16: ...ACH WILL DAMAGE PLASTIC AND RUBBER COMPONENTS Rinse all parts that contact bleach thoroughly with clean potable water CAUTION Read the WARNINGS on the bleach container before using CAUTION Handle sani...

Страница 17: ...y The connection to the battery is a snap type connector See Figure 11 20 Remove the battery by sliding it out of its holder 21 Replace the battery with a new alkaline 9 volt transistor battery P N 31...

Страница 18: ...hes Lube and Reseat O Ring Replace O Ring Leak at saddle tapping valve Loose clamp Tubing deformed Tighten clamp screws do not crush source water tubing Cut damaged area off of tube or replace tube an...

Страница 19: ...D SERVICED BY COMPANY SERVICE PERFORMED CLEANING ONLY CLEANING SANITIZING REPAIR FILTERS REPLACED CARBON Pb1 LEAD CARBON 5s VOC s COMMENTS DATE SERVICED SERVICED BY COMPANY SERVICE PERFORMED CLEANING...

Страница 20: ...eet Hydrotech specifications If the drinking water system is altered by anyone other than Hydrotech the warranty shall be void ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHAN...

Отзывы: