11
ACTIVATING THE SYSTEM
Turn on the Source Water
NOTE:
Make sure all water lines and fittings are secure
and free from leakage.
1. Open source water supply valve. Check for leakage.
2. Open product water faucet and let water flow to drain
for at least 10 minutes. This will expel the air from the
system.
3. Close product water faucet. In 5 minutes, check the
connections for leaks and correct if necessary.
Connect The Smartap
®
Monitor Battery
NOTE:
Battery is mounted inside the module cover.
Battery may be connected prior to installation.
1. Loosen three mounting bracket screws. Gently pull
module cover up and away from the module body.
2. Connect the battery by pressing the clip onto the
battery terminals (See Page 13, Figure 11).
3. Replace module cover and tighten bracket screws.
4. To test connection, activate monitor by pressing test
button or opening product water faucet. If an indicator
light illuminates, connection is good.
SERVICING THE SYSTEM
MAINTENANCE - WARRANTY INFORMATION
Recommended Service Intervals
Hydrotech
®
Warranty
Replace filters as required based on Smartap
®
Water Flow Monitor indications
or every 6 to 12 months depending on feed water quality.
System: 2 years limited
Smartap
®
: 5 years
FAUCETS
Non-Air Gap Faucet
Part Number
Non-Air Gap Faucet
Part Number
Non-Air Gap Faucet
Part Number
Stainless Steel, Faucet Only
Stainless Steel, with Light Bar
40301007
11702002
Chrome, Faucet Only
Chrome, with Light Bar
40301002
11702001
Polymer, Plain Front
Polymer, Light Bar
1140010*
1140032*
* Color Suffix Codes: 0 (Chrome/Black), 1 (White), 2 (Chrome/White), 3 (Almond), 4 (Black), 5 (Chrome/Black), 6 (Satin/Black), 7 (Chrome/White), and
8 (Satin/White). Codes 0, 2, 6, and 8 designate electro-plated faucets. Codes 5 and 7 designate vacuum-metalized faucets
PARTS AND SERVICE ARE AVAILABLE THROUGH YOUR HYDROTECH
®
DEALER.
ROUTINE MAINTENANCE
RECOMMENDATIONS
HAVE ALL COMPONENTS ON HAND AND READY BEFORE BEGINNING PROCEDURE.
A CLEAN WORK AREA AND EQUIPMENT ARE ESSENTIAL TO PROPERLY CLEAN AND/OR SANITIZE THE SYSTEM.
(I.e., CLEAN HANDS, TOOLS, WORK SURFACE, AND CONTAINERS)
SERVICE REQUIREMENTS
To insure the system operates at its optimum level,
certain routine maintenance must be performed.
Frequency of maintenance performance will depend on
feed water quality and level of system usage.
CLEAN:
Each time filters are replaced
SANITIZE:
At least once every 12
months.
EQUIPMENT NEEDED
Safety glasses
Rubber gloves, sanitary
Wash Cloth, Clean and Lint-free
Household bleach - Unscented Only
(5 1/4% sodium hypochlorite)
Liquid dish soap
Plastic bucket, Plastic bowl
“O” Ring Lube FDA Approved
(P/N 30300026)
REPLACEMENT FILTER SETS
“O” RINGS
P/N 41400011 Carbon Filter, VOC Reduction (White Caps)
P/N 41400010 Carbon Filter, Lead Reduction (Black Caps)
P/N 34201010 Carbon Cartridge
P/N 34201026 Filter Housing