PROBLEM SOLVING
Equipment system will not operate:
1. Make sure the Power Air Switch is turned “ON”
2. Check the Ground Fault Circuit Interrupter, if equipped, to see if the reset button has
popped out. If it has, press reset button inward. If the GFCI trips repeatedly, contact
a service technician to correct the problem.
3. Check the main circuit breaker panel. If the circuit breaker has tripped reset the
breaker. If the circuit breaker trips repeatedly, contact a service technician to correct
the problem.
4. For cord connected units check the receptacle.
5. Make sure the high-limit has not tripped. Push to reset.
Pump will run but there is no water flow:
1.
Make sure system is installed below water level.
2.
Make sure all valves are in the open position.
3.
Make sure that the filter is clean.
4.
Check the suction fittings to make sure that they are not clogged with debris.
5.
Check the water level and make sure it is above the jets and at the proper level on
the skimmer opening.
6.
Check the pump for trapped air. With the pump running, loosen the pump bleed
screw to release any trapped air. When there is water flow to the jets tighten the
bleed screw securely. You may need to use a sponge to collect the water from the
bleed screw.
Pump runs and there is water flow but no heat:
1. Turn the thermostat to a higher temperature setting. Do not expect to feel hot water
coming from the jets.
2. Check to see if the high limit switch reset button, located on the front of the control
box, has popped outward. If so, reset by pressing inward.
3. Check to make sure that all the valves are open and that there is full flow. Limited
water flow may not activate the pressure switch to allow the heater to come on.
The water will not maintain the proper temperature
:
1. A thermal cover is required to maintain the water temperature.
2. Turn the thermostat to a higher setting.
85-0130 REV.10
5/11
18
Содержание BES6000-HC Series
Страница 9: ...BES COMPONENT CONNECTIONS 85 0130 REV 10 5 11 8...
Страница 10: ...FLOAT SWITCH LEVEL KIT PLUMBING DIAGRAM 85 0130 REV 10 5 11 9...
Страница 11: ...PRESSURE SWITCH LEVEL KIT PLUMBING DIAGRAM 85 0130 REV 10 5 11 10...
Страница 12: ...SYSTEM INTERFACE MODULE SEE NEXT PAGE FOR IMPORTANT TIPS 85 0130 REV 10 5 11 11...
Страница 22: ...85 0130 REV 10 5 11 21...