240 VOLT INSTALLATION - Permanently Connected Units
1. Remove the faceplate from the control box to allow access to the input wiring.
2. Connect input wiring to the terminal block as shown below. A three wire electrical
service plus ground is required for a 208-240-volt connection (line 1, line 2, neutral,
and ground). Failure to connect a neutral line will cause the control box to
malfunction and may void the warranty.
3. Reinstall the control box faceplate.
120 VOLT INSTALLATION - Permanently Connected Units
1. Remove the faceplate from the control box to allow access to the input wiring.
2. Connect input wiring to the terminal block as shown below. A two wire electrical
service plus ground is required for a 120-volt connection (line 1, neutral, and
ground). Place a 14awg minimum jumper wire between Neutral and Line 2 at the
incoming terminal block.
**Heater will not operate without this jumper**
3. Reinstall the control box faceplate.
85-0130 REV.10
5/11
7