39
Remote
Green
LED
Malfunction
descrip
tion
Diagnosis
510
Six Flashes
Abnormal main gas
solenoid valve
551
Six Flashes
Abnormal gas
solenoid valve
• Check for conne
ction/b
reakage of wires (Part #708)
and/
or burn marks on the computer board (Part #701).
611*
Four Flashes
Fan motor fault
• Check for conne
ction/b
reakage of wires (Part #714)
and/
or burn marks on the computer board (Part #701).
• Check for c
onnection/b
reakage of wires, dust buildup
in the fan motor (Part #103) and
/
or burn marks on the
computer board (Part #701).
• Check for frozen
/
corrosion of connectors (Part #103).
701*
One Flash
Computer board fault
711*
One Flash
• Check the outlet thermistor (Part #408) as it may need to
be cleaned.
• Check for conne
ction/b
reakage of wires (Part #714).
Gas solenoid valve
drive circuit failure
721*
• Refer to the 111 and 121 error codes.
Six Flashes
False
flame
det
ection
741
N
/
A
• Check if condensate drain is installed on the vent collar of
the water heater.
• Check if there is leaking from heat exchanger (Part #401).
Miscommunica
tion
between boiler
and remote controller
751
N
/
A
• Inspect the c
onnections
between the boiler and
remote controller.
• Check the power supply of the water heater.
Miscommunica
tion
between boiler
and built-in controller
• Inspect the c
onnections
between the boiler and
built-in controller.
• Check the power supply of the water heater.
991
Five Flashes
Imperfect
combus
tion
• Check the gas type of the boiler.
• Inspect the environment around the boiler.
Determine how long the unit has been installed.
• Check the
altitude/
eleva
tion
of the area of where the
water heater is installed.
• Check if there is any blockage in the intake air and
/
or
exhaust.
• Check whether there is enough distance between the
exhaust and air intake terminals.
• Check if there is grease and
/
or dirt in the burner (Part
#101) and the fan motor (Part #103), especially if the
boiler has been installed in a contaminated area.