Space Heating Applications
•
In order to purge air in water pipes within a closed loop system, an air vent,
air separator, and expansion tank should be installed in the system.
(Hydro
Smart pre-built space heating panels incorporate all of these features).
•
Water temperature over 125° F (52° C) can cause sever burns instantly of
death from scalding.
•
Chemicals such as diluted Glycol can be used for radiant floor, Hydro/fan
coil air or Baseboard heating only. The diluted solution of glycol must contain
between 25% and 55% of Glycol. Be aware that in a closed loop system, low
pressure in the heat exchanger can cause low-temperature boiling, resulting
in excessive noise and damage to the micro boiler. Consult with the glycol
maker for specifications prior to use.
Hydro Smart Pre-Built Space Heating Panels
Hydro Smart pre-plumbed panels help make space heating easy and reliable. These panels are
professionally engineered and use proven Primary/Secondary hydronic practices. Call Tech Support
(1-763-331-3066) for assistance.