10
Bank of DIP switches
HS115 PLUS Computer board
NOTE:
The dark squares indicate the correct DIP switch
positions.
Check the eleva
tion
where your boiler is inst
alled.
Set your DIP switches according to
altitude
as
shown below
.
DIP Switch Settings
0 to 2,000
ft.
(0 to 610 m)
(DEFAULT)
2,001 to
3,000
ft.
(611 to 914 m)
3,001 to
5,000
ft.
(915 to 1,524 m)
5,001 to
7,500
ft.
(1,525 to 2,286 m)
7,501 to
10,100
ft.
(2,287 to 3,078 m)
HS115 PLUS
ON 1 2 3 4 5 6 7 8 9 10
OFF
No.
3 : OFF
No.
4 : OFF
No.
5 : OFF
ON 1 2 3 4 5 6 7 8 9 10
OFF
No.
3 : OFF
No.
4 : ON
No.
5 : OFF
ON 1 2 3 4 5 6 7 8 9 10
OFF
No.
3 : OFF
No.
4 : OFF
No.
5 : ON
ON 1 2 3 4 5 6 7 8 9 10
OFF
No.
3 : OFF
No.
4 : ON
No.
5 : ON
ON 1 2 3 4 5 6 7 8 9 10
OFF
No.
3 : ON
No.
4 : ON
No.
5 : ON
Altitude
DIP
s
wit
ches
HIGH-ALTITUDE INSTALLATIONS
Ins
talla
tion
altitude
The maximum cer
tifi
ed or
allowable installed al
ti
tude
is 10,100
ft.
(3,078 m)