Page 22
Hydro Systems Co. 2018
8.1 Legal Requirements
8.1.1.
If the power supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
8.1.2.
New hose-sets supplied with the appliance are to be used and that old hose-sets should not be reused.
8.2 Advised
8.2.1.
Unit frontage cleaned with a dry cloth (can be done without disconnection).
8.2.2.
Clean / Replace chemical pickup hoses.
8.2.3.
Clean / Replace inlet strainer.
8.2.4.
Clean / Replace outlet hose to machine.
8.2.5
Clean / Replace venturis as required.
CAUTION
Before any maintenance, isolate the incoming power source and disconnect. All trigger signals should also be
isolated.
UNIT
Voltage / Frequency / Current
115v-230vAC / 50-60Hz / 0.085 – 0.158A
Water Pressure (Min/Max)
Min. (Low Flow 2L/Min)
0.18 mPa (1.8 Bar / 26.1 PSI)
Max.
0.6 MPa (6 Bar / 87 PSI)
Min. (High Flow 4L/Min)
0.2 mPa (2.0 Bar / 29 PSI)
Electrical Class
Class II
SYSTEM CABINET
Cabinet Material
Front
ASA
Rear
PP-TF
Size (mm)
4 Product
Height
220
Width
270
Depth
162
6 Product
220
360
162
8 Product
220
565
162
IP RATING
IP22