![Hydro EvoClean 1214GB Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/hydro/evoclean-1214gb/evoclean-1214gb_user-manual_2191793009.webp)
Page 9
Hydro Systems Co. 2018
5.4.5.
Take chemical container lid and drill 20mm (¾’’) hole for PVC Hose to pass through, ensure tube is not a tight fit (to
avoid vacuum).
Note:
Do not drill lid when screwed onto chemical container to avoid swarf.
5.4.6.
Replace lid on container, and place the inlet tube into the container.
5.5.
Installation Step 5: Trigger Connections
5.5.1.
The EvoClean uses the following trigger signal inputs.
Trigger
Supply Signal
(+)
Supply Signal
(-)
Connected in
RELAY
mode:
Connected in
NORMAL
mode:
Trigger 1
Black
Red
Solenoid 1
Pre-Wash
Trigger 2 Hot
White
Green
Solenoid 2
Main-Wash
Trigger 2 Cold
Orange
Blue
Solenoid 2
Main-Wash
Trigger 3 Spare
Brown
Yellow
Solenoid 3
Main-Wash
Trigger 4
Violet
Slate (Grey)
Solenoid 4
Final Rinse
5.5.2.
All signal inputs are optically isolated high impedance input circuits. Supply signal voltages may range from 24-240
VAC, 50-60 Hz (20 mA maximum draw) or 12-24 VDC, (5 mA maximum draw) that accommodate the range typically
found in most washing machines. Each signal input connects to a signal input wire and the common. With DC signals,
polarity must be observed. The signals should be positive voltages (+). The Common is negative (-).
5.5.3.
Use appropriate terminal connectors to connect the signal wires to the laundry machine.
5.5.4
If one or more triggers are not used, they do not need to be connected but should be suitably secured.