![Hydro EvoClean 1214GB Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/hydro/evoclean-1214gb/evoclean-1214gb_user-manual_2191793013.webp)
Page 13
6.5.1. User Screens
Under user screen the installer has the functionality to prime the individual chemicals during setup and also view and
reset the wash counts per formula.
6.5.2. Machine Size -
This is set to the size of the washer extractor being installed. This can be set from 1 - 200kg. All
chemical delivery settings refer to this figure when calculating the amount of chemical to be injected during a formula.
6.5.3. Operational Mode
- As detailed in section 6.1. Any unused screens in either mode are hidden.
6.5.4. Edit Products -
This is where the chemical specific settings are inputted. The chemicals are numbered from 1 upwards
and each one includes the following settings:
a) Prewash amount.
b) Main-wash amount.
c) Final rinse amount.
* The amounts are inputted in mls/kg and calculates the chemical to be injected in conjunction with the machine size in
kgs. Special mls/kg amounts can be set within formulas to allow the user extra functionality*
d) Delay time - Although the chemical will be diluted with water anywhere from 2.5:1 up to 4:1 depending on the
application, there may be situations where the installer requires a delay time to be added between when the trigger
signal is received and the operation of the valve. This can be set from 1 to 999 seconds.
e) Chemical cost - This can be set from 0.01 to 999. Inputting a figure here will allow the unit to calculate the cost of
chemical usage and output the results as a report.
f) Drum size - When set, this will allow the unit to calculate the amount of chemical left within the drum. When 5% of the
volume is left the unit will alarm to tell the user that the chemical is running low.
g) Custom name - The chemical can be given a custom name (up to 10 characters).
h) Calibration - See section 6.7.
Intermediate Flush -
(Firmware V1.37 onwards): Additional functionality has been added to the delay function of the
EvoClean. An intermediate flush option has been added so that if the delay time is set at between 40 - 999 seconds the
unit will deliver a flush cycle between chemicals. The sequence of operations will be (40 - 999 seconds):
i. The preceding chemical will run.
ii. The unit will then flush for the length of time set (or
length of delay if longer than delay time).
iii. The remainder of the delay time will elapse.
iv. The next chemical will run.