6.5.5. Edit Formulas
6.5.5.1 Enable/Disable -
This allows the user to enable or disable a particular formula. If the formula is disabled, it will not
show on the unit when the user scrolls through the formulas.
6.5.5.2
As detailed in section 5.5.1, in Normal mode a signal received on one of the 4 Input Pins will inject programmed
amounts of product.
For Prewash signal, change the ‘x‘ to a ‘P‘ if that numbered product is required in that formula. This will automatically
select the mls/kg amount as set within ‘edit products‘. Repeat the process for the Mainwash, Spare and Final Rinse
signal.
Note:
This is a display example from a 4 product unit.
F
01
P Chemicals:
1
P
2x3x4x
If a custom mls/kg amount is required within a specific formula the unit will allow this. In addition to the ‘x’ or ‘P’ you
can also select ‘s’.
When the select button is pressed in order to move to the right, if an ‘s’ has been selected an additional screen is
shown. This will allow the user to adjust the mls/kg amount.
F
01
P Chemicals:
1s2x3x4x
F
01
P:C1 mls/kg:
10
i
h
Set
6.5.7
Edit Settings
6.5.7.1
Signal filter - This is where the signal filter time can be set. The signal is un-verified until it reaches the filter time at which
point it becomes verified.
6.5.7.2
Default formula - After a wash cycle has ended the EvoClean will reset. The user can set the unit to revert to the
following states:
1. A preferred formula selected from all enabled formulas.
2. ‘Select at start’ - The unit will not accept any trigger signals until a formula is selected.
3. ‘Previous formula’ - The unit will stay on the previous formula.
6.5.7.3
Allow user prime - This feature can be enabled or disabled as required. If enabled it will hide the relevant screen
preventing the user from using this feature.
6.5.7.4
Change passcode - this allows the installer to change the passcode. A passcode of ‘0000‘ cannot be set but all others
are available. The default passcode is 1234.
6.5.7.5
Set lockout - Can be set between 5 - 99 minutes.
6.5.7.6
Product alarms - this feature can be enabled or disabled as required. If enabled it will hide the relevant screen preventing
the user from using this feature.