HYDAC FILTER SYSTEMS GMBH
Piping and product description | 3
MoWa OLS10-Z-x 4573340 en-us web
25 / 72
3.4 Technical data
If you are aware of the technical data of the product, you will be
able to use it optimally. This section contains the technical details
for the product:
This has the following technical data depending on the type of the
Offline Separator.
Hydraulic connections
INLET OIL – M36x2 (28L) according to
ISO 8434-1
OUTLET OIL – M36x2 (28L) according to
ISO 8434-1
DRAIN WATER – M26x1.5 (18L) accord-
ing to ISO 8434-1
Permitted operating flu-
ids
Mineral oils according to DIN 51524 or
gear oils according to DIN 51517 with a
density ≤950 kg/m³ and a water content
of <15 volume%.
Permissible pressure at
port DRAINWATER
0 bar
Permissible viscosity
range
5 l/min = 15 … 500 mm²/s
15 l/min = 15 … 200 mm²/s
Permitted fluid tempera-
ture range
0 to 80 °C (ice formation is not permitted)
Permitted operating
pressure
≤ 6 bar
Permitted ambient tem-
perature range
-10 … 70°C
Permitted storage tem-
perature range
0 … 50°C
Permissable relative hu-
midity
≤ 90 %, non-condensing
Air conditions
Clean, salt-free air, not near oxidizing
substances (rust film)
Storage duration
Unlimited.
Replace all the seals before commission-
ing after a storage duration of ≥2 years.
Sealing material
FPM
Housing material
Stainless
1
2
3
4
5
6
7
8
9
A