5 | Assembly/Installation
HYDAC FILTER SYSTEMS GMBH
40 / 72
MoWa OLS10-Z-x 4573340 en-us web
– Mount the gasket (6) and dossing insert (5) congruent to the
magnets.
9
Fig. 11:
Terminal assignment of the water drain valve (assignment of the dosing
insert)
7 Terminal 1
8 Terminal 2
9 Protective conductor terminal
1. Slide the pressure screw (1), the disks (2) and the housing of
the connector plug (4) onto the cable.
2. Fasten the protective conductor (insulation yellow/green) to
the protective conductor terminal (9).
3. Fasten the other wires to the terminals (7) and (8) of the dos-
ing insert (5).
DANGER! Take care of the connections marked with + or
- on the correct pin connection of the energized conduc-
tor.
4. Set the housing (4) in the selected position (9 O'clock,12
O'clock, 3 O'clock, 6 O'clock) on the dosing insert (5).
5. Turn the pressure screw (1) tightly on the cable introduction.
NOTICE! The cable introduction must be securely sealed.
6. Pull the protective cap off the plug connections of the mag-
nets.
7. Push the gasket (6) and the housing (4) with the dosing in-
sert onto the magnets.
DANGER! Take care that the gasket lies flat over the en-
tire surface between the magnet and the connector plug,
1
2
3
4
5
6
7
8
9
A