8 | Performing Maintenance
HYDAC FILTER SYSTEMS GMBH
50 / 72
MoWa OLS10-Z-x 4573340 en-us web
17. Tighten the housing clamp evenly with the wrench
= 13
mm with a maximum of 20 Nm.
Screw on the lock nut and secure the connection.
18. Open the shut-off valves at the ports INLET OIL and OUT-
LET OIL.
19. Bleed the coalescing housing through the air-vent plug
(2310) on the cover.
O
The replacement of the coalescing element is completed.
1
2
3
4
5
6
7
8
9
A