HYDAC FILTER SYSTEMS GMBH
Assembly/Installation | 5
MoWa OLS10-Z-x 4573340 en-us web
37 / 72
Install the suction port connection at the lowest part of the oil tank.
Through this, you ensure that the water phase located at the base
of the tank is reached and drawn off.
NOTICE
Excessively high input pressure at the INLET OIL connection
The coalescing housing will be damaged.
u
Note the maximum permissible operating pressure, see
5.3.2 Connecting the pressure port – OUTLET OIL
Make sure that the nominal width of the pressure line corresponds
to the connector thread of the housing.
Install the return line below the oil level in the oil tank to prevent
air from entering the oil in the tank.
If the clogging indicator pressure displayed for the a clean filter el-
ement is > 1 bar, use a differential pressure clogging indicator.
5.3.3 Connecting the water drainage - (DRAIN WATER)
Connect the water outlet to a depressurized reservoir without
cross-section reduction. Container height ≤ 1.5 m and no higher
than the fluid level in the oil tank.
NOTICE
Excess pressure at the water outlet
The coalescing tank will be damaged.
u
Guide the water outlet into a depressurized reservoir.
Environmentally tip
The separated water can contain some parts of operating fluid
Environmental hazard
u
Dispose of the water-oil mixture in an environmentally friendly
manner.