Installation and Maintenance Manual
50
Troubleshooting
The Smart Touch Controller system includes many self diagnostic capabilities. The LCD will display
specific messages and the Audio Alert buzzer will sound distinctive chirps. Any Alerts, Faults or Errors
are also logged into a memory and stamped with a time and date. For diagnostic purposes, these
messages can be retrieved with optional WinLogger
¥
software available from Hy-Security Gate.
The following chart is a listing of codes that would appear on the LCD display if problems
are detected by the Smart Touch Controller.
Error, Fault, or Alert Status
LCD Display
Buzzer Chirp Sequence
Cannot respond due to tripped
sensor or in Entrapment mode
Entr
2 chirps/sec every 2 seconds while control
input is active
Safety Mode Alert
SAFE
2 chirps once when in Safety Mode
Low 24V Control Voltage Alert
Lo24 (ac or dc)
N/A (LCD flashes once every 5 seconds)
Critical Low 24V supply power
BadP (ac or dc) N/A Display steady – controls disabled
Dead 24V Battery Alert –DC only bat - dEAd
3 chirps upon any operating command
Gate forced open Alert
ALE1
2 pulses/sec for 30 seconds
Gate drift closed Alert
ALE2
2 pulses/sec for 10 seconds
Motor thermal overload Alert
ALE4
2 chirps/sec every 15 seconds
Both limits tripped Alert
ALE5
2 chirps/sec every 15 seconds
Limits not released in 10 seconds ALE6
2 chirps/sec every 15 seconds
Loop abnormal freq change alert
ALE7
2 chirps/sec every 15 seconds
Loop shorted to ground alert
ALE8
2 chirps/sec every 15 seconds
Loop disconnected alert
ALE9
2 chirps/sec every 15 seconds
Loop detector comm. alert
AL10
2 chirps/sec every 15 seconds
Loop detector function alert
AL11
2 chirps/sec every 15 seconds
Loop detector active >5 minutes
AL12
2 chirps/sec every 15 seconds
Maximum run Fault
FAL1
1 chirp once every 15 seconds
Photo eye Fault (supervised)
FAL2
2 chirps/sec once per minute
Critical AC sag – bad supply wire FAL3
2 chirps/sec once per minute
Directional motion Error
Err1
3 chirps/sec once per minute
Disconnected IES Error
Err2
3 chirps/sec once per minute
Loop detector failed
Err3
3 chirps/sec once per minute
Master/slave RS485 comm. Error Err4
3 chirps/sec once per minute
EEPROM Data Error (factory)
Err7
3 chirps/sec once per minute
EEPROM Data Error (installer)
Err8
3 chirps/sec once per minute
EEPROM Data Error (user menu) Err9
3 chirps/sec once per minute
Program Data Error
FAiL
3 chirps/sec once per minute
The green LED near #2 on the terminal strip is the heartbeat of the processor. This LED should
always blink brightly to indicate normal operation.
GATE SPEED:
The speed in which a hydraulic operator moves a gate is determined by the size of the
pump and the size of the actuator components. Just like a gear box, this speed is not adjustable.
Attempting to slow a gate by changing any valve setting will cause a great deal of inefficiency and heat. If
the speed of a gate must be changed, contact your Hy-Security distributor. Extremely cold weather is
unlikely to seriously affect the speed of the gate, because Hy-Security employs a special grade of
hydraulic oil that we call UNIFLOW oil, which maintains a very linear viscosity over a broad range of
temperatures. Because of this high quality oil and other design considerations, we rate our operators for
service in ambient temperatures of –40F degrees to 130F degrees. If the speed of your operator has
been affected by cold weather, verify that the gate hardware s not impaired by ice and verify that the
reservoir it is filled with UNIFLOW oil. In severe conditions, consider adding a heater.
Содержание HRG 220 ST
Страница 15: ...Installation and Maintenance Manual 9 Swing Gate Post Details ...
Страница 16: ...Installation and Maintenance Manual 10 HRG 220 Pump Pack ...
Страница 17: ...Installation and Maintenance Manual 11 HRG 222 Pump Pack ...
Страница 18: ...Installation and Maintenance Manual 12 How Our Hydraulic Swing Gates Work ...
Страница 25: ...Installation and Maintenance Manual 19 Instructions for Hand Pump or Manual Operation ...
Страница 29: ...Installation and Maintenance Manual 23 ...
Страница 47: ...Installation and Maintenance Manual 41 ...
Страница 48: ...Installation and Maintenance Manual 42 ...
Страница 62: ...Installation and Maintenance Manual 56 Battery Connection Diagram ...
Страница 63: ...Installation and Maintenance Manual 57 Battery Connection Diagram ...
Страница 65: ...Installation and Maintenance Manual 59 Wire Size Schedules ...
Страница 66: ...Installation and Maintenance Manual 60 Parts Breakout HRG 220 Pump Packs ...
Страница 67: ...Installation and Maintenance Manual 61 Parts Breakout HRG 222 Pump Packs ...
Страница 68: ...Installation and Maintenance Manual 62 Parts Breakout Control Box ...
Страница 69: ...Installation and Maintenance Manual 63 Parts Breakout Post ...
Страница 70: ...Installation and Maintenance Manual 64 Parts Breakout DC Power Supply ...