APPENDIX A. – Temperature Guidelines
Refrigerated

The refrigerators should be operated according to Hussmann’s published
engineering specifications for entering air temperatures for specific
equipment applications. Table 1 shows the typical temperature of the air
entering the food zone one hour before the start of defrost and one hour
after defrost for various categories of refrigerators. Refer to Appendix C for
Field Evaluation Guidelines.

TABLE 1

TYPE OF

TYPICAL ENTERING

REFRIGERATOR

 AIR TEMPERATURE

I. OPEN DISPLAY

A. Non frozen:

1) Meat

28°F

2) Dairy/Deli

32°F

3) Produce

a. Processed

36°F

b. Unprocessed

45°F

B. Frozen

0°F

C. Ice Cream

-5°F

II. CLOSED DISPLAY

A. Non frozen:

1) Meat

34°F

2) Dairy/Deli

34°F

3) Produce

a. Processed

36°F

b. Unprocessed

45°F

B. Frozen

0°F

C. Ice Cream

-5°F

Single Deck

Multi Deck

Service Case

Reach-In

I. Open Display Styles

II. Closed Display Styles

APPENDIX B. – Application Recommendations
Refrigerated

1.0 Temperature performance is critical for controlling bacteria growth.

Therefore, the following recommendations are included in the standard.
They are based on confirmed field experience over many years.

1.1 The installer is responsible for following the installation instructions and

recommendations provided by Hussmann for the installation of each
individual type refrigerator.

1.2 Refrigeration piping should be sized according to Hussmann’s

equipment recommendations and installed in accordance with normal
refrigeration practices. Refrigeration piping should be insulated
according to Hussmann’s recommendations.

1.3 A clogged waste outlet blocks refrigeration. The installer is responsible

for the proper installation of the system which dispenses condensate
waste through an air gap into the building indirect waste system.

1.4 The installer should perform a complete start-up evaluation prior to

the loading of food into the refrigerator, which includes such items
as:
a) Initial temperature performance, coils should be properly fed with a

refrigerant according to Hussmann’s recommendations.

b) Observation of outside influences such as drafts, radiant heating

from the ceiling and from lamps. Such influence should be properly
corrected or compensated for.

c) At the same time, checks should be made of the store dry-bulb

and wet-bulb temperatures to ASCSertain that they are within the
limits prescribed by Hussmann.

d) Complete start-up procedures should include checking through a

defrost to make certain of its adequate frequency and length
without substantially exceeding the actual needs. This should
include checking the electrical or refrigerant circuits to make sure
that defrosts are correctly programmed for all the refrigerators
connected to each refrigeration system.

e) Recording instruments should be used to check performance.

APPENDIX C. – Field Recommendations -
Refrigerated

Recommendations for field evaluating the performance of retail
food refrigerators and hot cases

1.0 The most consistent indicator of display refrigerator performance is

temperature of the air entering the product zone (Refrigerated see
Diagram 1, Appendix A). In practical use, the precise determination of
return air temperature is extremely difficult. Readings of return air
temperatures will be variable and results will be inconsistent. The
product temperature alone is not an indicator of refrigerator
performance.

NOTE

: Public Health will use the temperature of the product in

determining if the refrigerator will be allowed to display potentially
hazardous food. For the purpose of this evaluation, product temperature
above the FDA Food Code 1993 temperature for potentially hazardous food
will be the first indication that an evaluation should be performed. It is
expected that all refrigerators will keep food at the FDA Food Code 1993
temperature for potentially hazardous food.

1.1 The following recommendations are made for the purpose of arriving

at easily taken and understood data which, coupled with other
observations, may be used to determined whether a display refrigera-
tor is working as intended:
a) INSTRUMENT – A stainless steel stem-type thermometer is

recommended and it should have a dial a minimum of 1 inch
internal diameter. A test thermometer scaled only in Celsius or

Appendices

Содержание ASCS

Страница 1: ...Chino ASCS DELI MEAT FISH SERVICE CASE REV 0303 Installation Operation Manual ASCS DELI MEAT FISH SERVICE CASE P N IGSV ASCS 0303 INSTALLATION OPERATION GUIDE...

Страница 2: ...exist and is found to be the responsibility of Hussmann Chino notify Hussmann Chino If such a shortage involves the carrier notify the carrier immediately and request an inspection Hussmann Chino will...

Страница 3: ...nent position as possible Keep in place attached case until ready to set bolt to adjoining case TIGHTEN GLASS SCREWS Tighten screws along clamshell located on the underside of glass before placing uni...

Страница 4: ...hinge operation and glass alignment problems NOTE A To avoid removing concrete flooring begin lineup leveling from the highest point of the store floor B When wedges are involved in a lineup set them...

Страница 5: ...e adjoining case is a hot case the cases are bolted together by mans of a bracket located behind the front panel Remove the front panel by lifting it up and out COMMON END BETWEEN UNLIKE CASES AND HOT...

Страница 6: ...ff the center of the case to allow use of the P trap pipe section Never use two water seals in series in any one line Double P traps in series will cause a lock and prevent draining 3 Always provide a...

Страница 7: ...light savings time Military time 24 hr clock or 12 hour clock may be selected by pressing and holding the h key while depressing the h key A flashing light indicated a missing selection in the program...

Страница 8: ...NLESS 225 01 0603 COMPRESSION FITTING PVC 1 2 OD x 1 2 NPT 225 01 1322 SOLENOID VALVE ALCO 222CB B B AMS 225 01 1340 UNION TEE COMPRESSION PVC 1 2 OD x 1 2 OD 225 01 1324 COMPRESSION FITTING PVC 1 2 O...

Страница 9: ...energy consumption Set defrost cycles as listed in the Case Specifications Data for your particular case The number of defrosts per day should never change The duration of the defrost cycle may be adj...

Страница 10: ...REAR INTERIOR WALL OF CASE VIEWED FROM FRONT BALL VALVE HAMMON 225 01 2026 1 4 100 X 1 8FPT SW ADAPTER 225 01 2089A 1 4 OD X 1 8 FPT SW ADAPTER 225 01 3059 1 8 MPT X 1 4 COMP PVC ADAPTER 225 01 3059...

Страница 11: ...valves are furnished as standard equipment unless otherwise specified by customer EXPANSION VALVE ADJUSTMENT Expansion valves must be adjusted to fully feed the evaporator Before attempting any adjus...

Страница 12: ...r external appliances BEFORE SERVICING Always Disconnect Electrical Power at the Main Disconnect when servicing or replacing any electrical component This includes but not limited to Fans Heaters Ther...

Страница 13: ...dges of the bumper must be firmly seated into the retainer by applying with a rubber mallet not by hand 7 The bumper should be struck by the mallet at a slight angle that forces the bumper back into i...

Страница 14: ...tic as it does not allow for proper circulation Make sure the cloth or paper is in direct contact with the product 10 Turn and rotate the meat fairly often The blood which gives the pink color works i...

Страница 15: ...ial coatings on the glass surface itself To preserve this coating and the optical clarity keep the glass clean Windex or Glass Plus are the only solutions recommended for use in cleaning non glare gla...

Страница 16: ...an blades with the raised embossed side of the blade TOWARD THE MOTOR COPPER COILS The copper coils used in Hussmann merchandisers may be repaired in the field Materials are available from local refri...

Страница 17: ...tled lubricant in the cylinders and prevent any stress on the front glass 1 3 RE ADJUSTMENT After Initial STARTUP In addition to verifying that theAllen screws on the lift up glass are tightened when...

Страница 18: ...Back of Case Inside of Case Chrome cap for access to nut plate nut plate CUT VIEW Mini Top Hardware Adjust glass Up and Down vertically Adjust glass Side to Side horizontally Adjust glass Front to Ba...

Страница 19: ...0 Out 1 208 13 0 Meat Fish 33 26 26 26 Air Evap fans 8 x 15 3 4 3 36 50 In 230 Humidity 3 1 4 Axial 2 NOTE Case temperature is controlled by a factory installed thermostat and suction solenoid excludi...

Страница 20: ...04 0111 125 04 0112 125 01 0110 SUCTION SOLENOID HUMIDITY FAN 125 04 0110 BALLAST LH3 120 L 1 125 04 0142 THERMOSTAT DUPLEX RECEPTACLES NOT USED GFCI DEDICATED LINE 125 04 0113 NOT USED 125 04 0113 N...

Страница 21: ...0110 SUCTION SOLENOID HUMIDITY FAN 125 04 0110 BALLAST LH3 120 L 2 125 04 0142 THERMOSTAT DUPLEX RECEPTACLES NOT USED GFCI DEDICATED LINE 125 04 0113 NOT USED 125 04 0113 NOT USED 125 04 0100 SINGLE...

Страница 22: ...SWEEP HEATER OPTIONAL HEATER SWITCH OPTIONAL 125 04 0115 125 04 0115 AIR SWEEP ANTI SWEAT FANS 125 04 0121 LEDGE LIGHT OPTIONAL SEE DWG W0100016 EVAPORATOR FAN PLENUM EXTENSION 125 04 0148 EVAPORATOR...

Страница 23: ...EP HEATER OPTIONAL HEATER SWITCH OPTIONAL 125 04 0115 125 04 0115 AIR SWEEP ANTI SWEAT FANS 125 04 0121 LEDGE LIGHT OPTIONAL SEE DWG W0100016 EVAPORATOR FAN PLENUM EXTENSION 125 04 0148 EVAPORATOR FAN...

Страница 24: ...15 125 04 0115 AIR SWEEP ANTI SWEAT FANS 125 04 0121 LEDGE LIGHT OPTIONAL SEE DWG W0100016 EVAPORATOR FAN PLENUM EXTENSION 125 04 0148 EVAPORATOR FAN PLENUM EXTENSION 125 04 0148 EVAPORATOR FAN CAP BA...

Страница 25: ...L 125 04 0115 125 04 0115 AIR SWEEP ANTI SWEAT FANS 125 04 0121 LEDGE LIGHT OPTIONAL SEE DWG W0100016 EVAPORATOR FAN PLENUM EXTENSION 125 04 0148 EVAPORATOR FAN PLENUM EXTENSION 125 04 0148 EVAPORATOR...

Страница 26: ...R WEDGE FAN 3 AXIAL FAN WEDGE FAN HARNESS 125 04 0124 EVAPORATOR FAN PLENUM EXTENSION 125 04 0148 IF REQUIRED EVAPORATOR FAN PRIMARY FAN HARNESS 125 04 0147 CABLE SPLITTER 125 04 0119 USE AIR SWEEP HA...

Страница 27: ...L CASE WATER FLUSH SYSTEM REDRAWN TO SPEC FROM 10 21 99 BY AEC 04 15 02 AEC M 5 4 3 2 1 12 00 5 4 3 2 1 GR SSLIN TIME CLOCK 125 04 0100 125 04 0119 PRIMARY FAN HARNESS EVAPORATOR FAN 125 04 0127A SOLE...

Страница 28: ...8T5 830 FP28T5 830 FP28T5 830 FP2IT5 830 FP2IT5 830 CAP UNUSED RED LEAD CAP UNUSED RED LEAD 4 CASES 6 CASES 8 CASES 10 CASES 12 CASES RED YELLOW YELLOW RED RED YELLOW RED RED 125 04 0119 BALLAST FULHA...

Страница 29: ...USE 1 2 3 WHITE DEDICATED GFCI 4 5 6 YELLOW RECEPTACLES 7 10 ORANGE LIGHTS 8 11 PURPLE ANTI SWEAT HTR FAN 9 12 BROWN EVAP FANS T STAT 1 2 3 4 5 6 7 8 9 10 11 12 B B B W G 3 2 1 3 2 1 3 2 1 3 2 1 3 2...

Страница 30: ...LOR USE 1 2 3 WHITE DEDICATED GFCI 4 5 6 YELLOW RECEPTACLES 7 10 ORANGE LIGHTS 8 11 PURPLE ANTI SWEAT HTR FAN 9 12 BROWN EVAP FANS T STAT 1 2 3 4 5 6 7 8 9 10 11 12 B B B W G 3 2 1 3 2 1 3 2 1 3 2 1 3...

Страница 31: ...used Not used 125 04 0117 125 04 0115 Anti sweat Fans Optional 125 04 0115 125 04 0115 125 04 0119 Heater Wire case rear Tubular Heater Element Front air sweep heater Optional 125 04 0122 125 04 0123...

Страница 32: ...00 Not used Not used 125 04 0115 Anti sweat Fans Optional 125 04 0115 125 04 0115 125 04 0119 Heater Wire case rear Tubular Heater Element Front air sweep heater Optional 475 01 1421 2 Anti sweat Heat...

Страница 33: ...25 04 0112 125 04 0113 125 04 0113 125 04 0112 125 04 0110 125 04 0100 125 04 0121 125 04 0115 125 04 0115 125 04 0115 125 04 0119 Heater Wire case rear Tubular Heater Element Front air sweep heater O...

Страница 34: ...12 125 04 0113 125 04 0113 125 04 0112 125 04 0110 125 04 0100 125 04 0115 Heater Wire case rear Anti sweat Fans Optional 125 04 0121 125 04 0115 Tubular Heater Element Front air sweep heater Optional...

Страница 35: ...n s recommendations b Observation of outside influences such as drafts radiant heating from the ceiling and from lamps Such influence should be properly corrected or compensated for c At the same time...

Страница 36: ...t been modified to use replacements for CFC 12 CFC 502 or other refrigerant If so have the modifications been made in accordance with the recommendations of Hussmann equipment Is the refrigerator char...

Страница 37: ...omes in contact with the tool or equipment i Make sure that all refrigeration equipment is installed and adjusted in strict accordance with Hussmann s recommendations j See that all storage and refrig...

Страница 38: ...IGSV ASCS 0303 38...

Страница 39: ...tion under this warranty shall be limited to a period not to exceed five years from date of factory shipment On Hussmann refrigeration systems an additional 4 year extended warranty for the motor comp...

Страница 40: ...ticular unit They can be found on a small metal plate on the unit Please note them below for future reference MODEL SERIAL NUMBER Chino Additional copies of thispublication may be obtained by contacti...

Отзывы: