TROUBLESHOOTING

15 - English

PROBLEM

CAUSE

SOLUTION

Compressor will not run

Loss of power or overheating 

No electrical power 

Blown shop/house fuse
Shop/house breaker open 

Amperage overload open

Pressure switch bad
Tank is full of air

Check  for  proper  use  of  extension 
cord
Check to be sure unit is plugged in Check 
fuse/breaker
Replace shop/house blown fuse
Reset shop/house breaker, determining 
why problem happened
Unit must be unplugged and allowed to 
cool for 30 minutes to initiate reset.
Replace pressure switch
Compressor  will  turn  on  when  tank 
pressure drops to cut-in pressure

Motor  hums  but  cannot  run  or  runs 
slowly

Low voltage
Wrong gauge wire or length of extension 
cord
Shorted or open motor winding
Defective check valve or unloader

Check with voltmeter
Check for proper gauge wire and cord 
length
Take compressor to service center
Take compressor to service center

Amperage overload protector cuts out 
repeatedly

Low voltage
Lack  of  proper  ventilation/room 
temperature too high

Wrong gauge wire or length of extension 
cord

Check with voltmeter
Move  compressor  to  well-ventilated 
area.  Unit  must  be  unplugged  and 
allowed to cool for 30 minutes to initiate 
reset.
Check for proper gauge wire and cord 
length

Air tank pressure drops when compressor 
shuts off

Loose  connections  (fittings,  tubing, 
etc.)
Loose drain valve/Open drain valve
Check valve leaking

Check  all  connections  with  soap  and 
water solution and tighten
Tighten drain valve/Close drain valve
Take compressor to service center

 

DANGER:

Do  not  disassemble  check  valve, 
tank drain valves or safety relief valve  
with air in tank — bleed tank

Excessive moisture in discharge air

Excessive water in air tank
High humidity

Drain tank
Move to area of less humidity; use air 
line filter

Compressor runs continuously

Defective pressure switch
Excessive air usage

Piston rings are worn

Take compressor to service center
Decrease  air  usage;  compressor  not 
large enough for tool’s requirement

Replace  piston  rings;  Call  customer 
service for assistance

Air output lower than normal

Broken inlet valves
Connections leaking

Take compressor to service center
Tighten connections

Содержание H301PL

Страница 1: ...ank you for your purchase GUARDE ESTE MANUAL PARA FUTURAS CONSULTAS Su compresor de aire ha sido dise ada y fabricada de conformidad con nuestras estrictas normas para brindar fiabilidad facilidad de...

Страница 2: ...y la fiabilidad por lo cual se facilita su manejo y mantenimiento Introduction 2 Introducci n General Safety Rules 3 4 Reglas de seguridad generales Specific Safety Rules 4 5 Reglas de seguridad espec...

Страница 3: ...ront and side Always use eye protection which is marked to comply with ANSI Z87 1 Additional safety protection will be required in some environments For example the working area may in clude exposure...

Страница 4: ...pressure greater than marked maximum pressure of attachment and or the item being inflated Never use at pressure greater than 135 psi Use an air pressure gauge periodically while inflating an item to...

Страница 5: ...one heavy enough to carry the current your product will draw A wire gauge size A W G of at least 14 is recommended for an extension cord 25 feet or less in length A cord exceeding 50 feet is not recom...

Страница 6: ...uid in a confined area Spray area must be well ventilated Do not smoke while spraying or spray where spark or flame is present Keep compressors as far from the spraying area as possible at least 15 fe...

Страница 7: ...ary to properly filter and purify the air to meet minimal specifications for Grade D breathing as described in Compressed Gas Association Commodity Specification G 7 1 1966 OSHA 29 CFR 1910 134 Compre...

Страница 8: ...roduct is powered by a precision built electric motor It should be connected to a power supply that is 120 V AC only normal household current 60 Hz Do not operate this product on direct current DC A s...

Страница 9: ...Pounds Per Square Inch Measurement of the pressure exerted by the force of the air The actual psi is measured by a pressure gauge on the compressor Pump Produces the compressed air with a reciprocatin...

Страница 10: ...PUMP The oil free pump reduces the need for maintenance pressure regulator knob Use the pressure regulator knob to adjust the amount of air being delivered through the hose Pressing down on the knob...

Страница 11: ...duct for the purposes listed below Operating some air powered tools Operating air accessories such as air nozzles and inflators TRANSPORTING THE AIR COMPRESSOR See Figure 3 4 page 18 The air compresso...

Страница 12: ...F position NOTE When the compressor is in the AUTO position the air compressor will automatically turn back on when the tank air pressure drops below the preset pressure limit It will also shut off ag...

Страница 13: ...allow pressurized air to escape Release the ring The safety release valve must reset and hold n Allow unit to reach max pressure as indicated on the tank pressure gauge n Set regulator to desired pre...

Страница 14: ...g has been released or if the valve is stuck and cannot be actuated by the ring Do not use the air compressor until the safety valve has been replaced Use of the air compressor in this condition could...

Страница 15: ...n room temperature too high Wronggaugewireorlengthofextension cord Check with voltmeter Move compressor to well ventilated area Unit must be unplugged and allowed to cool for 30 minutes to initiate re...

Страница 16: ...ed in this operator s manual This warranty does not apply to any damage to the One World Technologies Inc product that is the result of improper maintenance or to any One World Technologies Inc produc...

Страница 17: ...n contra sujetadores y desechos que salgan disparados los cuales pueden causar lesiones oculares serias Tanto el patr n como el operador deben asegurarse de que se use protecci n ocular adecuada Recom...

Страница 18: ...rlo podr a resultar en da os a la herramienta Antes de usar la unidad revise las mangueras para ver muestran da os o desgaste asegur ndose de que est n seguras todas las conexiones No utilice la unida...

Страница 19: ...ineaci n de las partes m viles que no haya atoramiento de las mismas que no haya piezas rotas el montaje de las piezas y cualquier otra condici n que pudiera afectar su funcionamiento Toda protecci n...

Страница 20: ...ea de rociado debe estar bien ventilada No fume mientras est rociando con pistola ni roc e donde haya presentes chispas o flamas Mantenga los compresores tan lejos del rea de pintura y de vapores expl...

Страница 21: ...la cual si no se evita causar la muerte o lesiones serias ADVERTENCIA Indica una situaci n peligrosa posible la cual si no se evita podr a causar la muerte o lesiones serias PRECAUCI N Indica una sit...

Страница 22: ...de corriente como la mostrada en la figura 1 Tambi n dispone de una patilla de conexi n a tierra como la mostrada Este producto debe conectarse a tierra Cordones de extensi n S lo utilice cordones de...

Страница 23: ...rada psi Son las unidades de medida de la presi n ejercida por la fuerza del aire La presi n real en psi es medida por el man metro del compresor Bomba Es el dispositivo que produce el aire comprimido...

Страница 24: ...duce la necesidad de realizar tareas de mantenimiento PERILLA DEL REGULADOR DE PRESI N Uselaperilladelreguladordepresi nparaajustarlacantidad de aire que se suministra a trav s de la manguera Si se pr...

Страница 25: ...deben corresponder a la capacidad del compresor de aire Este producto puede emplearse para los fines siguientes Accionamiento de algunas herramientas de aire Utilizaci n de accesorios de aire como boq...

Страница 26: ...der el compresor Como se muestra en la secci n de puesta en marcha de la etiqueta de referencia r pida NOTA El compresor no debe ponerse en funcionamiento si est en posici n vertical n Para apagar el...

Страница 27: ...servicio a la unidad Si no se purga la presi n de los tanques antes de intentar retirar las v lvulas pueden producirse lesiones serias n Aseg rese de que la presi n de salida sea cero 0 psi girando la...

Страница 28: ...res o cinco segundos para permitir el escape del aire presur izado Suelte el anillo La v lvula de descarga de seguri dad debe reajustar y mantener el nivel de la presi n antes de que todo el aire comp...

Страница 29: ...nsuficiente temperatura ambiental demasiado elevada Cord n de extensi n de calibre o longitud equivocados Revise con volt metro Lleve el compresor a un lugar bien ventilado se debe permitir que el mot...

Страница 30: ...seg n se especifica en este manual del operador Esta garant a no aplica a los da os en el producto de One World Technologies Inc que resulten de un mantenimiento indebido ni a producto alguno de One...

Страница 31: ...atory knob mando de regulaci n de presi n Q Quick coupler acoplador r pido R Bungee wrap cordon lastique D Safety Valve boquilla de la seguridad F Indicates an item on the quick reference label indiqu...

Страница 32: ...ompartimiento para accesorios A Coiled Hose manguera de aire A Auto Off switch interruptor de encendido apagado B Tank pressure gauge man metro del tanque C Regulatory pressure gauge regulador de pres...

Страница 33: ...lo a b Fig 11 d A Auto Off switch interruptor de encendido apagado B Tank pressure gauge man metro del tanque C Regulatory pressure gauge regulador de presi n manom trica D Pressure regulator knob man...

Страница 34: ...15 NOTES NOTAS...

Страница 35: ...15 NOTES NOTAS...

Страница 36: ...AIR COMPRESSOR 3 galones Compresor de aire H301PL ONE WORLD TECHNOLOGIES INC Hwy 8 Pickens SC 29671 Phone 1 866 340 3912 SERVICIO Ahora que ha adquirido este producto si alguna vez llega a necesitar...

Отзывы: