10.3 Selecting the Display Language
When the “Select Language” sub-menu was selected, the screen changes
to the display reproduced in Display 25.
Use the arrow keys
ñ
and
ò
to select one of the options, “Deutsch,”
“English,” and “Français” and confirm your selection by pressing the
START key.
10.4 Setting the Buzzer Volume
When the “Set Volume” sub-menu was selected, the screen changes
to the display reproduced in Display 26. The buzzer can also be heard.
Turn the buzzer volume up or down to the desired value using the
ï
,
ð
arrow keys (from 0 to 70) and confirm your setting by pressing the
START key.
10.5 Entering the Inventory Number
When the “Inventory No.” sub-menu was selected, the screen changes
to the display reproduced in Display 27. Enter the identification number
under which the unit was inventorized within the company, using the
alphanumeric input routine (see section 5.11), and confirm the number
by pressing the START key.
11 Self-Monitoring Functions Overview
11.1 Errors During Data Input
11.1.1 Code Error
Erroneous input, poor code tag, error in code symbology or improper
code reading.
11.1.2 No Contact
There is no properly established electric contact between the welding
unit and the fitting (check connection terminal pushed on fitting), or the
heater coil is defective.
11.1.3 Low Voltage
The input voltage is below 180 volts. Adjust generator output voltage.
11.1.4 Overvoltage
The input voltage is over 300 volts. Decrease generator output voltage.
11.1.5 Overheated
The inverter temperature is too hot. Let the welding unit cool down for
about 1 hour.
11.1.6 System Error
CAUTION!
The unit has to be disconnected immediately from the power supply and
the fitting. The auto-test has found a system error. The unit must no longer
be used and has to be sent to an authorized shop for check and repair.
11.1.7 Temperature Error
The ambient temperature measured is outside the operating range of the
welding unit, i.e., below -20°C or over +60°C.
Display 26
Display 27
ADJUST VOLUME
0-----35-----70
Turn up
à
Turn down
Inventory No.
*****************
Display 25
CHOOSE LANGUAGE
>Deutsch
English
Francais