U-ONE
®
-SAFETY-LWL
Configuration manual
10
USL_KonfigManual-en_R3
authentication.
The password must be between 6 and 12 ASCII characters (0x20 - 0x7E) long.
Level 0: Observer (no password)
The following functions are available:
Establishing communication with the modules
Entering a password
Displaying the set configuration
Displaying stored configurations
Level 1: Tester (password level 1)
In addition to level 0, the following functions are available here:
Complete switch test
Generate testing protocol
Level 2: Admin (password level 2)
In addition to level 1, the following functions are available here:
Changing the configuration
Saving configurations
The default passwords on delivery are “huebner1” for
password level 1 and “huebner2” for password level 2.
An open lock symbolises that the password “huebner2”
has not yet been changed, and that the configuration is
not secure against unauthorised changes.
A closed lock indicates that the configuration is secure against unauthorised changes. The
method for saving the configuration is described in section 2.2.4.
The authorisation level (level here: Admin) with which the user is logged into the modules is
displayed in clear text to the left of the lock symbol.
NOTE!
The default login password is
“huebner1” or “huebner2”.
NOTE!
You must change the Admin password to protect the configuration from
unauthorised access. (Section 2.2.2)
Fig. 2-4: Partial view header