U-ONE
®
-SAFETY-LWL
Configuration manual
14
USL_KonfigManual-en_R3
3.3 Start the US42Pro software
The home screen will appear after you
start the software.
Click “Connect” to establish
communication with the USL. The
display to the right of the button
indicates the connection status.
Display
Status
grey
not
connected
alternating
light green / dark
green
connected
System data are read out after the connection is established. Now, the user can enter the
Admin password to calibrate or configure the modules.
Calibration and configuration can only be carried out by
users on the “Admin” password level.
NOTE!
You must change the Admin password “huebner2” to protect the configuration and
calibration from unauthorised access. (Section 2.2.1)
3.4 Select operating mode
There are 2 different operating modes for the USL:
3.4.1 Speed mode
There are no position-dependent switching points or position-dependent current values 4 mA...
20 mA available in this operating mode. No calibration of the position system is required.
Working area limits are not monitored.
3.4.2 Position and speed mode
If position-dependent switching points or position-dependent current values 4 mA ... 20 mA are
used, the operating mode “Position and speed mode” must be selected. Calibration of the
position system is required in this operating mode (sec. 3.5).
NOTE!
The module can only be configured while shut down.
If a rotational movement is detected during configuration, the USL is switched to a
safe state.
Fig. 3-1: Home screen
Fig. 3-2: Login