INSTALLATION MANUAL
Page 9 of 15
HUBER+SUHNER disclaims any liability resulting from incorrect installation and use, including any damages resulting from the use of tools and
accessories other than the ones recommended herein. Any installation performed by unqualified personnel voids the product warranty provided by
HUBER+SUHNER. All due care and attention must be exercised when performing the installation of these products. For advice concerning the
general handling of these products please contact HUBER+SUHNER.
Step 6
Feed gland nut over cable to secure to cable entry gland if
required.
Step 7
Unwind black tape at cable butt to reveal rip cord.
This cord is used to open the cable jacket and gain access to
the cable elements within.
Step 8
Use a screwdriver (or similar) to cut the cable jacket back to the
“strip-back point” marked using the tape.
Step 9
Remove cable jacket carefully.
Step 10
Unwrap copper tape from cable using gloves due to potential
sharp edges up to the “strip-back point”.
Step 11
Make sure not to leave any sharp edges where the copper foil
goes under the jacket: carefully remove excess foil with pin-
nosed pliers and then cover it with tape.