INSTALLATION MANUAL
Page 10 of 15
HUBER+SUHNER disclaims any liability resulting from incorrect installation and use, including any damages resulting from the use of tools and
accessories other than the ones recommended herein. Any installation performed by unqualified personnel voids the product warranty provided by
HUBER+SUHNER. All due care and attention must be exercised when performing the installation of these products. For advice concerning the
general handling of these products please contact HUBER+SUHNER.
Step 12
Carefully unwind the fibre optic cable element from the DC tails
and from a loop to separate it.
Step 13
During this process (at any stage) ensure the fibre optics are not
kinked where they exit the cable butt.
Use tape to protect the FO cable against over bending
.
Do not over bend the cable. Minimum bend
radius for the fiber optic cable is 8 cm
Step 14
Once fiber optic cable is separated from DC wires, attach it
temporarily to base station to keep it secure and clean.
Step 15
Tighten cable gland to secure cable and ensure IP protection.
Step 16
Measure the required DC tail length and cut them.
Step 17
Do not cut at any stage the fiber optic cable
Step 18
Route DC cable element to their respective termination points
and connect.
Route earth wire to earth bonding point and connect
.