ViewPoint 8650C
User Guide
5 Holding a Simple Conference
Issue 10 (2013-07-20)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
37
Figure 5-1
RM Connection
Step 3
Set the connection parameters in
Table 5-3
Connection parameters
Parameter
Description
Setting
Connection
mode
It specifies the service
management mode of the MCU.
RMCC/IMS: The MCU is to be
connected to an external RM
system or an IMS network.
SMC2.0: The MCU is to be
connected to an SMC2.0
system.
•B -in Web: The service
management functions of the
MCU is to be used.
Select
RMCC/IMS
.
Network
interface
It specifies the network interface
used for the connection between
the MCU and an external RM.
FE
GE0
GE1
ANY
Default value:
ANY
.
Select
GE0
(recommended).
Listening port
Connection request service port
that the MCU uses to connect to
the conference management
system.
Value range: 1-65535
Default value:
5000
Password
Password for the MCU to connect
to the conference management
Example:
123456