Quidway S5700 Series Ethernet Switches
V100R006C00
Configuration Guide - DeviceManagement
Issue
01
Date
2011-07-15
HUAWEI TECHNOLOGIES CO., LTD.
Страница 1: ...Quidway S5700 Series Ethernet Switches V100R006C00 Configuration Guide Device Management Issue 01 Date 2011 07 15 HUAWEI TECHNOLOGIES CO LTD ...
Страница 2: ...be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject to change without notice Every effort has been made in the preparation of this document to ensu...
Страница 3: ...ndicates a hazard with a high level of risk which if not avoided will result in death or serious injury WARNING Indicates a hazard with a medium or low level of risk which if not avoided could result in minor or moderate injury CAUTION Indicates a potentially hazardous situation which if not avoided could result in equipment damage data loss performance degradation or unexpected results TIP Indica...
Страница 4: ...n braces and separated by vertical bars A minimum of one item or a maximum of all items can be selected x y Optional items are grouped in brackets and separated by vertical bars Several items or no item can be selected 1 n The parameter before the sign can be repeated 1 to n times A line starting with the sign is comments Change History Updates between document issues are cumulative Therefore the ...
Страница 5: ...2 2 Configuring NAP based Remote Deployment 14 2 2 1 Establishing the Configuration Task 14 2 2 2 Configuring and Starting the NAP Master Interface 15 2 2 3 Remote Login 17 2 2 4 Disabling NAP on the Slave Device 18 2 2 5 Checking the Configuration 18 2 3 Configuration Examples 19 2 3 1 Example for Configuring NAP based Remote Deployment in Static Mode 20 2 3 2 Example for Configuring NAP based Re...
Страница 6: ...age 42 4 2 9 Checking Alarms 42 4 2 10 Checking the Status of an Interface 42 5 Hardware Management 44 5 1 Hardware Management Overview 45 5 2 Hardware Management Features Supported by the S5700 45 5 3 Backing Up the Electronic Label 45 5 3 1 Establishing the Configuration Task 45 5 3 2 Backing Up the Electronic Label 46 5 4 Configuring Electrical Port Sleep 46 5 4 1 Establishing the Configuration...
Страница 7: ... Remote Port Mirroring 71 7 3 1 Establishing the Configuration Task 71 7 3 2 Configuring Remote Port Mirroring 71 7 3 3 Checking the Configuration 74 7 4 Canceling Port Mirroring 74 7 4 1 Establishing the Configuration Task 74 7 4 2 Canceling Port Mirroring 75 7 4 3 Checking the Configuration 75 7 5 Configuring Local VLAN Mirroring 75 7 5 1 Establishing the Configuration Task 76 7 5 2 Configuring ...
Страница 8: ...e Flow Mirroring 88 7 12 4 Creating and Applying a Traffic Policy 89 7 12 5 Checking the Configuration 89 7 13 Canceling Flow Mirroring 90 7 13 1 Establishing the Configuration Task 90 7 13 2 Canceling Flow Mirroring 91 7 13 3 Checking the Configuration 91 7 14 Changing or Deleting an Observing Port 92 7 14 1 Establishing the Configuration Task 92 7 14 2 Optional Deleting an Observing Port 92 7 14...
Страница 9: ...2 ALS Features Supported by the S5700 121 9 3 Configuring ALS 122 9 3 1 Establishing the Configuration Task 122 9 3 2 Enabling ALS on an Interface 123 9 3 3 Optional Setting the Restart Mode of the Laser 124 9 3 4 Optional Starting the Laser Manually 124 9 3 5 Optional Setting the ALS Pulse Interval and Width of the Laser 125 9 3 6 Checking the Configuration 126 9 4 Configuration Examples 126 9 4 ...
Страница 10: ...escribes how Auto Config runs on the S5700 1 3 Deploying Unconfigured Switches Same Network Segment This section describes how to deploy S5700s without configuration file 1 4 Deploying Unconfigured Switches Different Network Segments This section describes how to deploy unconfigured S5700s Quidway S5700 Series Ethernet Switches Configuration Guide Device Management 1 Auto Config Issue 01 2011 07 1...
Страница 11: ...iguration file and then downloads the configuration file from the FTP TFTP server NOTE Auto Config uses Option 67 to obtain the configuration file first If Option 67 is not configured Auto Config obtains the intermediate file For example if the MAC address of an S5700 is 0018 82C5 AA89 and the S5700 needs to download the configuration file S5700 cfg the contents of the intermediate file are as fol...
Страница 12: ...pecifies the password of the FTP user l Option 143 specifies the IP address of the FTP server l Option 145 version file l Option 146 identity l Option 147 authentication 1 2 Auto Config Features Supported by the S5700 This section describes how Auto Config runs on the S5700 Figure 1 1 shows the basic process of Auto Config Quidway S5700 Series Ethernet Switches Configuration Guide Device Managemen...
Страница 13: ...b file Is the configuration file obtained Yes Is there Web file information Yes Set the restart flag Yes Yes Specify it as next startup file Specify it as next startup file Start a new AutoConfig process Is the restart flag 1 No Yes No No No No No Send DHCP Request packets periodically Auto Config starts No Stop sending DHCP Request packets Yes No Yes Configure non authentication for VTYs Allocate...
Страница 14: ...on the VLANIF1 interface in Up state VLANIF1 then broadcasts DHCP Request packets presuming that the DHCP server has been configured with the address pool Option 150 or Option 14x and gateway information Then the DHCP server sends the related configurations to the switch including the IP address allocated to the switch IP address of the FTP TFTP server FTP user name and password and default gatewa...
Страница 15: ...o Config networking where the DHCP server FTP TFTP server and unconfigured switch are on the same network segment SwitchA SwitchC SwitchB DHCP Server FTP TFTP Server Operator Pre configuration Tasks Before deploying unconfigured switches complete the following tasks l Ensuring that there are routes from the DHCP server and FTP TFTP server to the switches l Ensuring that there is no cfg or zip file...
Страница 16: ...n 14x l When new switches obtain configuration files through TFTP the DHCP server must support Option 150 l When new switches obtain configuration files through FTP the DHCP server must support Option 141 Option 142 and Option 143 l If both Option 150 and Option 14x are configured on the DHCP server Option 150 takes precedence over Option 14x l If you use ordinary characters to configure Option 15...
Страница 17: ...t phases in the Auto Config process to confirm that Auto Config runs properly Procedure Step 1 Five minutes after unconfigured switches are powered on check address allocation on the DHCP server to confirm that the switches are connected to the DHCP server NOTE If the switches are connected to the DHCP server you can log in to the switches through Telnet but do not configure the switches Step 2 Fi...
Страница 18: ...to the DHCP server and functions as an FTP or a TFTP server to store configuration files After the DHCP server and FTP TFTP server are configured every switch obtains a configuration file through Auto Config The DHCP server FTP TFTP server and switches are deployed on different network segments Figure 1 3 Auto Config networking where the DHCP server FTP TFTP server and unconfigured switches are on...
Страница 19: ...er Therefore the configuration procedure is not described and only the configuration contents are provided NOTE The DHCP server must support either Option 150 or Option 14x Procedure l Enable DHCP server l Configure an address pool including the address range gateway and Option 150 or Option 14x NOTE Pay attention to the following points when configuring Option 150 or Option 14x l When new switche...
Страница 20: ...r Therefore the configuration procedure is not described and only the configuration contents are provided Procedure l Set the IP address of the FTP TFTP server For an FTP server the IP address must be the same as the value of Option 143 configured on the DHCP server for a TFTP server the IP address must be the same as the value of Option 150 configured on the DHCP server l Create and configure an ...
Страница 21: ...ly after the configuration file is downloaded otherwise only a temporary configuration file is saved because the configurations have not taken effect Step 3 If the user has specified the activation delay the configuration file will take effect after the delay If the user has not specified the activation delay the configuration file will take effect immediately by default Then run the display curre...
Страница 22: ...hrough NAP 2 2 Configuring NAP based Remote Deployment Using NAP you can remotely log in to devices with empty configurations to implement remote deployment 2 3 Configuration Examples This section provides upgrade and maintenance examples together with the configuration flowchart The configuration examples explain networking requirements configuration notes and configuration roadmap Quidway S5700 ...
Страница 23: ... costs of network operation maintenance and delivery 2 2 Configuring NAP based Remote Deployment Using NAP you can remotely log in to devices with empty configurations to implement remote deployment Context CAUTION After the device with an empty configuration is powered on and started you must make sure that its interfaces connected to the devices on the current network are Up and support NAP othe...
Страница 24: ... are secondary IP addresses for the master interface and the slave interface respectively and should be on the same network segment 2 2 2 Configuring and Starting the NAP Master Interface You can assign an IP address to the NAP master interface or use the IP address that is automatically allocated by the system to start the NAP master interface Context CAUTION If commands affecting the IP address ...
Страница 25: ... ip pool ip address mask length command to change the IP address pool NOTE After NAP is started on the master device the IP address pool cannot be changed 3 Run interface interface type interface number The interface view is displayed 4 Run nap port master The NAP Master interface is configured and started You can also specify the NAP IP addresses To use this method do as follows 1 Run system view...
Страница 26: ...ce has an empty configuration you can log in to the slave device from the master device without a user name and a password l If however the slave device is configured with user name s and password s you must enter the correct user name and password to perform a NAP based remote login to the slave device NOTE To ensure security for NAP the slave device having an empty configuration checks the sourc...
Страница 27: ...can view the NAP status globally or on a specified interface Prerequisite NAP based remote deployment has been completed Procedure Step 1 Using the display nap status command you can view the current NAP status Step 2 Using the display nap interface interface type interface number command you can view the NAP status of the specified interface End Example Run the display nap status command to view ...
Страница 28: ...ter Current status IP ASSIGNED Local port GigabitEthernet0 0 1 Peer port GigabitEthernet0 0 1 Local primary ip 12 12 12 5 Peer primary ip 12 12 12 6 Local secondary ip 12 12 12 9 Peer secondary ip 12 12 12 10 Hello time 3s Linked time 00 09 12 Port property Master Current status IP ASSIGNED Local port GigabitEthernet0 0 2 Peer port GigabitEthernet0 0 2 Local primary ip 10 10 10 5 Peer primary ip 1...
Страница 29: ...ollows 1 Configure a NAP master interface on Switch B 2 Configure an IP address for establishing a NAP connection on Switch B 3 Use NAP to log in to Switch C from Switch B by means of Telnet Data Preparation To complete the configuration you need the following data l Two primary IP addresses The two IP addresses are primary IP addresses for the master interface and the slave interface respectively...
Страница 30: ...0 02 33 Step 3 Log in to the slave device from the master device Configure Switch B SwitchB GigabitEthernet0 0 1 nap login neighbor Trying 12 12 12 10 Press CTRL K to abort Connected to 12 12 12 10 Info The max number of VTY users is 10 and the number of current VTY users on line is 1 Step 4 Disable NAP on the slave device Configure Switch C Quidway system view Quidway sysname SwitchC SwitchC undo...
Страница 31: ...AP master interface Do as follows on Switch B Quidway system view Quidway sysname SwitchB SwitchB interface gigabitethernet0 0 1 SwitchB GigabitEthernet0 0 1 nap port master Step 2 Logging in to the slave device from the master device Do as follows on Switch B SwitchB GigabitEthernet0 0 1 nap login neighbor Trying 10 167 253 10 Press CTRL K to abort Connected to 10 167 253 10 Info The max number o...
Страница 32: ...ation Files None Quidway S5700 Series Ethernet Switches Configuration Guide Device Management 2 NAP Configuration Issue 01 2011 07 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 23 ...
Страница 33: ...orted by the S5700 3 4 Typical Topology of a Stack This section describes two typical topologies of a stack 3 5 Configuring the Stacking Function on the S5700 This section describes how to configure the stacking function on the S5700 3 6 Configuration Examples This section provides an example for configuring a stack in a ring topology Quidway S5700 Series Ethernet Switches Configuration Guide Devi...
Страница 34: ...e stack interfaces and other interfaces are common user interfaces Member switches are connected through independent stack modules and stack cables 3 2 Principle of Stacking This section describes how a stack system is set up Prerequisites for Setting Up a Stack System To successfully create a stack system complete the following tasks l Configure the same software version for all the member switch...
Страница 35: ...ck Then data can be backed up and the active standby switchover can be implemented The switches are connected through stack cables in a ring or link topology A master switch is elected among all the member switches through the stacking protocol The master switch manages the stacking system by assigning stack IDs to member switches collecting information about the topology of the stack and informin...
Страница 36: ...switch re specifies a member switch as the standby switch and then recalculates the stack topology and informs all the other member switches of the change l When a slave switch quits a stack system the master switch only recalculates the stack topology and informs all the other switches of the change The quitting slave switch restarts immediately l When the master and standby switches quit a stack...
Страница 37: ...figured with the MAC address switchover time and the quitting switch does not rejoin the stack within the switchover timeout interval If the quitting switch rejoins the stack before the switchover timer expires the switch becomes a slave and the MAC address of the stack system remains unchanged In this case the MAC address of the stack system is the MAC address of a slave switch l When a slave swi...
Страница 38: ...ram of a stack system SwitchA SwitchC SwitchD SwitchB Ethernet stack link common link Stack A Switch A is disconnected from Switch B Switch C is disconnected from Switch D Switch B is directly connected to the Ethernet As shown in Figure 3 2 Switch A and Switch B form Stack B Switch C and Switch D form Stack C In this case Stack A is divided into Stack B and Stack C and the process of dividing a s...
Страница 39: ...ystem In the stack system where the original standby switch currently belongs the active standby switchover is implemented and the process of the stack system becoming stable is the same as that when the master switch quits the stack system IP Address and MAC Address Collision After a Stack System Is Divided The IP address and MAC address of a stack system is configured globally That is all the sw...
Страница 40: ... aggregation port group port security and ARP l The Switch supports the following security features of stacking 802 1x MAC authentication AAA DHCP snooping attack defense storm control broadcast storm suppression IPSG MFF MAC and ACL l The Switch supports the following IP service features of stacking DHCP client DHCP server DHCP relay DNS and ND l The Switch supports the following multicast featur...
Страница 41: ...igure 3 3 Ring Topology stack link common link SwitchA SwitchC SwitchD SwitchB Link Topology As shown in Figure 3 4 stack interfaces on the Switches are connected through leased stack cables NOTE Do not directly connect stack ports on the same switch to form a loop Figure 3 4 link Topology SwitchA SwitchB SwitchC PC1 PC2 stack link common link Quidway S5700 Series Ethernet Switches Configuration G...
Страница 42: ... all the member switches l Using the devices of the same type for example EI devices or SI devices as the member switches of a stack system The EI devices and SI devices cannot be used in the same stack system l Installing stack cards on all devices and connecting the devices through stack cables l Ensuring that all the stack devices can be started normally Data Preparation To configure the stacki...
Страница 43: ...is enabled NOTE If you run the undo stack enable command to disable the stacking function on the S5700 the configuration takes effect only after the S5700 is restarted If you run the stack enable command to enable the stacking function on the S5700 the configuration takes effect only after the S5700 is restarted End 3 5 4 Optional Configuring a Stack ID for the S5700 Context Stack IDs can be confi...
Страница 44: ...master switch only if the stack system is not created you can configure a stack priority on each device Procedure Step 1 Run system view The system view is displayed Step 2 Run stack slot slot id priority priority A stack priority is configured for a specified stack device By default the priority value of a device is 100 A great value indicates a high priority NOTE Before the stack system is creat...
Страница 45: ...configured Procedure Step 1 Run system view The system view is displayed Step 2 Run stack timer mac address switch delay delay time The MAC address switchover time of the stack system is configured By default the delay of the MAC address switchover is 10 minutes End 3 5 7 Checking the Configuration Prerequisite Run the following commands to check the previous configuration Procedure l Run the disp...
Страница 46: ... Switch B functions as a standby switch After the active standby switchover the MAC address of the stack system is immediately switched To avoid updating MAC addresses of the stack system frequently and wasting system resources set the MAC address switchover time of the stack system to 1 minute after the active standby switchover Figure 3 5 Networking of a stack in a ring topology SwitchA SwitchC ...
Страница 47: ...isplay stack Stack topology type Ring Stack system MAC 0018 82b1 6eb8 MAC switch delay time 1 min Stack reserve vlanid 4093 slot role Mac address Priority Device type 0 Slave 0018 82d2 2e85 100 S5700 1 Slave 0018 82c6 1f44 100 S5700 3 Standby 0018 82c6 1f4c 100 S5700 4 Master 0018 82b1 6eb8 100 S5700 Configuration Files None Quidway S5700 Series Ethernet Switches Configuration Guide Device Managem...
Страница 48: ...ion describes function of display commands 4 2 Checking the Status of the S5700 This section describes how to check the status of the S5700 by using the display commands Quidway S5700 Series Ethernet Switches Configuration Guide Device Management 4 Using display commands to check the status of the device Issue 01 2011 07 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 3...
Страница 49: ... S5700 is displayed End 4 2 2 Checking the Version of the S5700 Context You can run the display version command in any view to check the version of the S5700 The displayed information includes the type of a card startup duration version of the hardware and version of the software Procedure Step 1 Run display version slot slot id The version of the specified card is displayed End 4 2 3 Checking the...
Страница 50: ...text You can run the following command in any view to check the working temperature of the S5700 Procedure Step 1 Run display environment slot slot id The temperature of a temperature sending SIC is displayed End 4 2 5 Checking the Fan Status When the device temperature is high you can check whether the fan is functioning normally Procedure Step 1 Run display fan slot slot id verbose The fan statu...
Страница 51: ...S5700 Procedure Step 1 Run display memory usage slave slot slot id The memory usage is displayed End 4 2 9 Checking Alarms Context You can run the following command in any view to check alarms on the S5700 Procedure Step 1 Run display alarm urgent slot slot id time interval The alarms generated during device operation are displayed End 4 2 10 Checking the Status of an Interface Quidway S5700 Serie...
Страница 52: ... the Status of an Interface in the Current Interface View 1 Run system view The system view is displayed 2 Run interface interface type interface number The interface view is displayed 3 Run display this interface The status of the interface in the current interface view is displayed Quidway S5700 Series Ethernet Switches Configuration Guide Device Management 4 Using display commands to check the ...
Страница 53: ...scribes the hardware management features supported by the S5700 5 3 Backing Up the Electronic Label This section describes how to back up the electronic label of the S5700 5 4 Configuring Electrical Port Sleep This section describes how to configure electrical port sleep to save energy Quidway S5700 Series Ethernet Switches Configuration Guide Device Management 5 Hardware Management Issue 01 2011 ...
Страница 54: ...red data This helps you complete the configuration task quickly and accurately Applicable Environment Electronic labels of network devices play an important role in troubleshooting When faults occur on a network you can obtain hardware information quickly from electronic labels Therefore you need to back up electronic labels Pre configuration Tasks Before backing up the electronic label of the S57...
Страница 55: ...acked up to an FTP server End 5 4 Configuring Electrical Port Sleep This section describes how to configure electrical port sleep to save energy 5 4 1 Establishing the Configuration Task Before configuring electrical port sleep familiarize yourself with the applicable environment complete the pre configuration tasks and obtain the required data This helps you complete the configuration task quickl...
Страница 56: ...p is enabled By default the sleep function is disabled on an Ethernet port End 5 4 3 Checking the Configuration After enabling electrical port sleep you can run the following command to check the configuration Procedure l Run system view The system view is displayed l Run interface interface type interface number The interface view is displayed l Run display this Check whether port sleep is enable...
Страница 57: ...his section describes how to manage and configure the information center 6 3 Sending Information to the Information Center This section describes how to send information to the specified direction 6 4 Maintaining the Information Center This section describes how to clear the statistics 6 5 Configuration Examples This section provides examples for configuring the information center Quidway S5700 Se...
Страница 58: ...f Information Information is classified into eight severity levels as shown in Table 6 1 The severer the information level is the lower the severity level value is Table 6 1 Description of the severity levels of information Threshold Severity Level Description 0 Emergency A fatal fault such as a program exception or incorrect use of the memory occurs on the device The system must restart 1 Alert A...
Страница 59: ...el value is configured to 6 only the information with the severity level value from 0 to 6 is output Working Process of an Information Center The working process of the information center is as follows l The information center receives logs traps and debugging information from all modules l The information center outputs information with different severity levels to different information channels ...
Страница 60: ...ions see Table 6 2 Table 6 2 Association relationship between the information channels and output directions Channel Number Default Channel Name Output Direction Description 0 Console Console Outputs information to the local Console that can receive logs alarms and debugging information 1 Monitor Monitor Outputs information to the VTY terminals that can receive logs alarms and debugging informatio...
Страница 61: ...l channels For example configure parts of logs to be output to a log host either through Channel 2 loghost or through Channel 6 You can also change the name of Channel 6 for managing channel conveniently Format of Logs Syslog is a sub function of the information center It outputs information to a log host through port 514 Figure 6 2 shows the format of logs Figure 6 2 Format of the output logs Int...
Страница 62: ...Log level Indicates the severity levels of logs CCC Brief description Describes the information type l Information type L indicates the user log identifier slot XXX Location information Slot indicates the number of the slot that sends the location information YYYY Descriptor Indicates the detailed information output from each module to the information center Each module fills in this field before ...
Страница 63: ... separated by a blank space HostName Host name By default the name is Quidway There is a space between the sysname and module name ModuleName Module name Indicates the name of the module that generates an alarm Severity Severity of information Indicates the severity of alarms l Critical l Major l Minor l Warning l Indeterminate l Cleared Brief Brief information Provides brief information of the al...
Страница 64: ...ormation severity 4 Optional Language used in the logs and the address of the log host 5 Optional Size of the log buffer and the trap buffer 6 2 2 Enabling the Information Center Context Do as follows on the S5700 Procedure Step 1 Run system view The system view is displayed Step 2 Run info center enable The information center view is displayed NOTE The system sends the system information to the l...
Страница 65: ...n logs or traps to the information channels NOTE Run the undo info center source module name default channel channel number channel name command to disable the unnecessary modules and select one or more modules to send information to the information channels End 6 2 5 Optional Configuring the Timestamp for the Output Information Procedure Step 1 Run system view The system view is displayed Step 2 ...
Страница 66: ... module module name size value slot slot id Check the summary of the information in the log buffer display logbuffer summary level severity slot slot id Check the information in the trap buffer of the memory display trapbuffer size value 6 3 Sending Information to the Information Center This section describes how to send information to the specified direction 6 3 1 Sending Information to the Conso...
Страница 67: ...p 2 Run info center monitor channel channel number channel name Information is sent to the Telnet terminal Step 3 Run quit Return to the user view Step 4 Run terminal monitor The terminal is enabled to display information Step 5 Run terminal debugging or terminal logging or terminal trapping The terminal is enabled to display debugging information logs and traps NOTE Step 4 and Step 5 are not list...
Страница 68: ...nding Information to the Log Buffer Procedure Step 1 Run system view The system view is displayed Step 2 Run info center logbuffer channel channel number channel name size buffersize Information is sent to the log buffer End 6 3 5 Sending Information to the Trap Buffer Context Do as follows on the S5700 Procedure Step 1 Run system view The system view is displayed Quidway S5700 Series Ethernet Swi...
Страница 69: ...on is sent to the IPv6 log host Step 4 Run info center loghost source interface type interface number The source interface for sending logs is specified End 6 3 7 Checking the Configuration Run the following commands to check the previous configuration Action Command Check statistics in the information center display info center statistics Run the preceding command If the information center can se...
Страница 70: ... 4 Networking of sending logs to the log host Network Log Host Switch 1 0 0 1 8 VLANIF10 2 0 0 1 8 Configuration Roadmap The configuration roadmap is as follows 1 Enable the information center 2 Configure the information channel to ensure that the S5700 can correctly send logs to the log host Disable the sending of the traps and debugging information to the log host 3 Configure the log host Data P...
Страница 71: ...ending information to the log host on the S5700 Quidway vlan 10 Quidway vlan10 quit Quidway interface gigabitethernet0 0 1 Quidway GigabitEthernet0 0 1 port link type hybrid Quidway GigabitEthernet0 0 1 port hybrid untagged vlan 10 Quidway GigabitEthernet0 0 1 quit Quidway interface vlanif 10 Quidway vlanif10 ip address 2 0 0 1 255 0 0 0 Quidway vlanif10 quit Quidway info center loghost source vla...
Страница 72: ...nitor is on Quidway terminal logging Info Current terminal logging is on Configuration Files info center source default channel 2 log level debugging state on trap state off debug state off info center loghost source vlanif 10 info center loghost 1 0 0 1 vlan batch 10 interface vlanif10 ip address 2 0 0 1 255 0 0 0 interface GigabitEthernet0 0 1 port hybrid untagged vlan 10 return Quidway S5700 Se...
Страница 73: ...ng 7 7 Canceling VLAN Mirroring This section describes how to cancel local VLAN mirroring and remote VLAN mirroring 7 8 Configuring MAC Address based Local Mirroring This section describes how to configure local MAC address mirroring 7 9 Configuring RSPAN Based on MAC Addresses This section describes how to configure RSPAN based on MAC addresses 7 10 Canceling Mirroring Based on MAC Addresses This...
Страница 74: ...ring This section describes how to configure CPU mirroring 7 16 Cancelling CPU Mirroring This section describes how to cancel CPU mirroring 7 17 Configuration Examples This section provides several configuration examples for mirroring Quidway S5700 Series Ethernet Switches Configuration Guide Device Management 7 Mirroring Issue 01 2011 07 15 Huawei Proprietary and Confidential Copyright Huawei Tec...
Страница 75: ...ng port l Mirrored flow A mirrored flow is a packet flow that runs to a flow mirroring port and is observed When a flow becomes a mirrored flow it is copied to an observing port l Mirrored VLAN A mirrored VLAN is a VLAN to be observed Incoming traffic or outgoing traffic passing through a mirrored VLAN is copied to an observing port l Mirrored MAC address A mirrored MAC address is the source or de...
Страница 76: ... Flow Mirroring In the process of flow mirroring the S5700 copies the mirroring flow passing one or more interfaces and sends the copy to an observing port Figure 7 2 shows the diagram of flow mirroring Figure 7 2 Schematic diagram of flow mirroring Observe port Sniffer host Port Data flow Mirror port Copy of data flow Mirror port Switch Match traffic classification Quidway S5700 Series Ethernet S...
Страница 77: ...U Mirroring CPU mirroring is used to mirror all the packets received by the CPU CPU mirroring is implemented as follows l If an ACL rule is specified the packets that match the ACL rule are mirrored to a specified observing port l If no ACL rule is specified all the packets received by the CPU are mirrored to a specified observing port CPU mirroring facilitates debugging and fault location RSPAN A...
Страница 78: ...ng port on the destination switch receives mirrored packets Through the RSPAN function packets on a specified interface or VLAN with a specified source or destination MAC address or matching a classifier can be copied to an observing port on a remote device 7 2 Configuring Local Port Mirroring This section describes how to configure local port mirroring 7 2 1 Establishing the Configuration Task Ap...
Страница 79: ...er An observing port is configured Step 3 Run interface interface type interface number The view of the mirrored port is displayed Step 4 Run port mirroring to observe port index both inbound outbound Interface mirroring is configured on the mirrored port To monitor packets on multiple interface repeat Step 3 and Step 4 End 7 2 3 Checking the Configuration Run the following commands to check the p...
Страница 80: ...rt 2 Number of the mirrored port 3 ID of the RSPAN VLAN 7 3 2 Configuring Remote Port Mirroring Context A mirrored port can be a physical interface or an Eth Trunk interface To configure an Eth Trunk as a mirrored port you must run the interface eth trunk trunk id command to create the Eth Trunk first l If an Eth Trunk is configured as a mirrored port its member interfaces cannot be configured as ...
Страница 81: ... outbound Remote port mirroring is configured To observe incoming and outgoing packets on multiple interfaces repeat Step 6 and Step 7 l Configure the RSPAN VLAN and add the interfaces connected to the source switch and destination switch to the RSPAN VLAN NOTE The mirrored port cannot be added to the RSPAN VLAN Do as follows on the intermediate switch The configurations on the interfaces connecte...
Страница 82: ... displayed 3 Run quit Return to the system view 4 Run interface interface type interface number The view of the interface connected to the intermediate switch is displayed NOTE If no intermediate switch exists you enter the view of the interface connected to the source switch 5 Run port link type trunk The interface is configured as a trunk interface 6 Run port trunk allow pass vlan vlan id The in...
Страница 83: ...e number of the mirrored port and the mirroring direction are configured properly 7 4 Canceling Port Mirroring This section describes how to cancel port mirroring 7 4 1 Establishing the Configuration Task Applicable Environment When port mirroring is enabled on an interface of the S5700 and the incoming or outgoing packets passing through this interface do not need to be monitored you can cancel p...
Страница 84: ...uration Run the following commands to check the previous configuration Action Command Check information about the observing port display observe port Check information about port mirroring display port mirroring Run the display port mirroring command If port mirroring is cancelled properly the configuration is successful 7 5 Configuring Local VLAN Mirroring This section describes how to configure ...
Страница 85: ... To configure local VLAN mirroring you need the following data No Data 1 Type and number of an observing port 2 ID of a mirrored VLAN 7 5 2 Configuring Local VLAN Mirroring Procedure Step 1 Run system view The system view is displayed Step 2 Run observe port index interface interface type interface number An observing port is configured Step 3 Run vlan vlan id The view of the mirrored VLAN is disp...
Страница 86: ...ny active interfaces of the S5700 in a specified VLAN or some VLANs need to be monitored you can configure remote VLAN mirroring if the interface added to the monitored VLAN is not located on the same S5700 as the observing port NOTE S5700SI does not support remote VLAN mirroring Pre configuration Tasks Before configuring remote VLAN mirroring complete the following tasks l Creating a VLAN as the ...
Страница 87: ...number vlan vlan id An observing port is configured and the RSPAN VLAN is specified 6 Run vlan vlan id The RSPAN VLAN view is displayed 7 Run mirroring to observe port index inbound Remote VLAN mirroring is configured To observe incoming and outgoing packets of multiple VLANs repeat Step 6 and Step 7 l Configure the RSPAN VLAN on the intermediate switch and add interfaces to the RSPAN VLAN The con...
Страница 88: ...celing VLAN Mirroring This section describes how to cancel local VLAN mirroring and remote VLAN mirroring 7 7 1 Establishing the Configuration Task Applicable Environment When VLAN mirroring is enabled in a specified VLAN and all incoming packets in this VLAN do not need to be monitored on the S5700 or before deleting or changing the bound observing port you need to cancel VLAN mirroring Pre confi...
Страница 89: ...ed Local Mirroring This section describes how to configure local MAC address mirroring 7 8 1 Establishing the Configuration Task Applicable Environment When incoming packets with the specified source or destination MAC address in a VLAN need to be monitored on the S5700 you can configure local MAC address mirroring if the monitoring interface receiving these incoming packets is located on the same...
Страница 90: ...on MAC addresses is configured You can repeatedly perform Step 3 and Step 4 to monitor the incoming packets with multiple MAC addresses in multiple VLANs End 7 8 3 Checking the Configuration Run the following commands to check the previous configuration Action Command Check information about the observing port display observe port Check information about port mirroring display port mirroring If th...
Страница 91: ... MAC addresses you need the following data No Data 1 Type and number of an observing port 2 MAC address of the packet to be mirrored 3 ID of the VLAN that the packet with the MAC address to be mirrored belongs to 4 ID of an RSPAN VLAN 7 9 2 Configuring Remote MAC Address Mirroring This section describes how to configure remote MAC address mirroring Procedure l Configure remote MAC address mirrorin...
Страница 92: ...epeat Step 6 and Step 7 l Configure the RSPAN VLAN on the intermediate switch and add interfaces to the RSPAN VLAN The configuration is the same as that for remote port mirroring For details see 7 3 2 Configuring Remote Port Mirroring l Configure the remote observing port on the destination switch The configuration is the same as that for remote port mirroring For details see 7 3 2 Configuring Rem...
Страница 93: ...observing port you need to cancel mirroring based on MAC addresses Pre configuration Tasks None Data Preparation To cancel mirroring based on MAC addresses you need the following data No Data 1 MAC address of the mirrored packet to be deleted 7 10 2 Canceling Mirroring Based on MAC Addresses Procedure Step 1 Run system view The system view is displayed Step 2 Run vlan vlan id The view of the VLAN ...
Страница 94: ...ing these incoming flows is located on the same S5700 as the observing port Pre configuration Tasks None Data Preparation To configure local flow mirroring you need the following data No Data 1 Type and number of the observing port 2 Type and number of the flow mirroring interface 3 Names of the traffic classifier traffic behavior and traffic policy 7 11 2 Configuring Traffic Classification Rules ...
Страница 95: ...nd then apply the policy to the interface For detailed configuration procedures see 7 11 4 Creating and Applying a Traffic Policy 7 11 4 Creating and Applying a Traffic Policy Context Do as follows on the S5700 that needs to be configured with flow mirroring Procedure Step 1 Run system view The system view is displayed Step 2 Run traffic policy policy name A traffic policy is created and the polic...
Страница 96: ...ion Action Command Check information about the observing port display observe port Check information about port mirroring display port mirroring Check the flow mirroring configuration in the traffic policy on an interface display traffic policy interface interface type interface number inbound If the following results are obtained the configuration is successful l The observing port is configured ...
Страница 97: ...r of the flow mirroring interface 3 Names of the traffic classifier traffic behavior and traffic policy 4 ID of the RSPAN VLAN 7 12 2 Setting Traffic Classification Rules Context For how to configure traffic classification rules see 7 11 2 Configuring Traffic Classification Rules 7 12 3 Configuring Remote Flow Mirroring Procedure l Configure remote flow mirroring on the source switch NOTE The mirr...
Страница 98: ...pply the policy to the interface For details see 7 11 4 Creating and Applying a Traffic Policy l Configure the RSPAN VLAN on the intermediate switch and add interfaces to the RSPAN VLAN The configuration is the same as that for remote port mirroring For details see 7 3 2 Configuring Remote Port Mirroring l Configure the remote observing Interface on the destination switch The configuration is the ...
Страница 99: ...licy contains a proper traffic classifier and a traffic behavior and the traffic behavior contains the flow mirroring action 7 13 Canceling Flow Mirroring This section describes how to cancel flow mirroring 7 13 1 Establishing the Configuration Task Applicable Environment When flow mirroring is enabled and the flow with the same attributes passing through the S5700 does not need to be monitored yo...
Страница 100: ...y and flow mirroring action on the interface are canceled To cancel a traffic policy you must cancel the traffic policy on all the interfaces where the traffic policy is applied and then run the undo traffic policy policy name command to cancel the traffic policy in the system view End 7 13 3 Checking the Configuration Run the following commands to check the previous configuration Action Command C...
Страница 101: ...rface on the S5700 as an observing port you can change the current observing port Pre configuration Tasks Before changing or deleting an observing port complete the following tasks l 7 4 Canceling Port Mirroring l 7 7 Canceling VLAN Mirroring l 7 10 Canceling Mirroring Based on MAC Addresses l 7 13 Canceling Flow Mirroring Data Preparation To change or delete an observing port you need the followi...
Страница 102: ...re Step 1 Run system view The system view is displayed Step 2 Run observe port index interface interface type interface number Another interface is specified as an observing port End 7 14 4 Checking the Configuration Run the following commands to check the previous configuration Action Command Check information about the observing port display observe port Check information about port mirroring di...
Страница 103: ...ta No Data 1 Optional ACL number and ACL rule 2 Index type and ID of the observing port 7 15 2 Optional Configuring an ACL Rule Context Do as follows on the S5700 that needs to be configured with CPU mirroring Procedure Step 1 Run system view The system view is displayed Step 2 Run acl number acl number An Access Control List ACL is created and the ACL view is displayed For details on the acl comm...
Страница 104: ... Run system view The system view is displayed Step 2 Run port mirroring cpu acl acl number to observe port index inbound CPU mirroring is configured By default CPU mirroring is disabled End 7 15 5 Checking the Configuration Run the following commands to check the previous configuration Action Command Check information about port mirroring display port mirroring Check information about CPU mirrorin...
Страница 105: ...ation To cancel CPU mirroring you need the following data No Data 1 Number of the observing port 7 16 2 Cancelling CPU Mirroring Procedure Step 1 Run system view The system view is displayed Step 2 Run undo port mirroring cpu CPU mirroring is cancelled Step 3 Optional Run undo observe port index The index of the observing port is deleted End 7 16 3 Checking the Configuration Run the following comm...
Страница 106: ...eds to be monitored In this case you can configure local port mirroring with GigabitEthernet 0 0 1 as a mirrored port and GigabitEthernet 0 0 24 as an observing port Figure 7 4 Networking diagram of local port mirroring Router Switch GE0 0 3 GE0 0 1 GE0 0 24 L2 Switch Mirroring host Configuration Roadmap The configuration roadmap is as follows 1 Configure GigabitEthernet 0 0 24 as an observing por...
Страница 107: ...ort mirroring to observe port 1 inbound Switch GigabitEthernet0 0 1 quit 4 Verify the configuration Run the display port mirroring command You can check the configurations on the observing port and mirrored port Switch display port mirroring Observe index 1 is set to interface GigabitEthernet0 0 24 Observe Type Local Interface GigabitEthernet0 0 1 Mirrored to Observe index 1 Direction inbound Obse...
Страница 108: ...eparation None Configuration Procedure 1 Add GigabitEthernet0 0 1 and GigabitEthernet0 0 2 to VLAN 10 as access interfaces Add GigabitEthernet0 0 1 to VLAN 10 as an access interface Switch system view Switch interface gigabitethernet 0 0 1 Switch GigabitEthernet0 0 1 port link type access Switch GigabitEthernet0 0 1 port default vlan 10 Switch GigabitEthernet0 0 1 quit Add GigabitEthernet0 0 2 to ...
Страница 109: ...erface GigabitEthernet0 0 2 port link type access port default vlan 10 return 7 17 3 Example for Configuring MAC Address based Local Mirroring Networking Requirements As shown in Figure 7 6 GigabitEthernet 0 0 1 is connected to PC1 GigabitEthernet 0 0 2 is connected to PC2 GigabitEthernet 0 0 4 is connected to a router GigabitEthernet 0 0 1 GigabitEthernet 0 0 2 and GigabitEthernet 0 0 4 belong to...
Страница 110: ...bitEthernet 0 0 3 3 Configure a mirroring MAC Configure local MAC address mirroring in the view of VLAN 10 Switch VLAN 10 Switch VLAN10 mac mirroring 0001 0001 0001 to observe port 1 inbound Switch VLAN10 quit 4 Verify the configuration Run the display port mirroring command You can view the configuration of the observing port Switch display port mirroring Observe index 1 is set to interface Gigab...
Страница 111: ... 7 17 4 Example for Configuring Local Flow Mirroring Networking Requirements As is shown in Figure 7 7 the Switch is connected to two L2 switches through GigabitEthernet 0 0 1 and GigabitEthernet 0 0 5 Packets with the same attributes received by GigabitEthernet 0 0 1 and GigabitEthernet 0 0 5 and transmitted from GigabitEthernet 0 0 3 need to be monitored In this example packets with the 802 1p p...
Страница 112: ...t 0 0 3 and GigabitEthernet 0 0 5 to the same VLAN in trunk mode Data Preparation To complete the configuration you need the following data l Name of the traffic classifier c1 l Name of the traffic behavior b1 l Name of the traffic policy p1 l ID of the VLAN created on the Switch 1 Configuration Procedure 1 Create a VLAN on the Switch and add interfaces to the VLAN in trunk mode Add GigabitEtherne...
Страница 113: ...y traffic policy p1 to GigabitEthernet 0 0 1 and GigabitEthernet 0 0 5 and enable GigabitEthernet 0 0 1 and GigabitEthernet 0 0 5 to trust the 802 1p priority of packets Switch interface gigabitethernet 0 0 1 Switch GigabitEthernet0 0 1 traffic policy p1 inbound Switch GigabitEthernet0 0 1 trust 8021p Switch GigabitEthernet0 0 1 quit Switch interface gigabitethernet 0 0 5 Switch GigabitEthernet0 0...
Страница 114: ...e GigabitEthernet0 0 3 port link type trunk port trunk allow pass vlan 10 interface GigabitEthernet0 0 5 port link type trunk port trunk allow pass vlan 10 traffic policy p1 inbound trust 8021p interface GigabitEthernet0 0 24 return 7 17 5 Example for Configuring Remote Port Mirroring Networking Requirements As shown in Figure 7 8 Switch A is connected to PC1 Switch C is connected to PC2 Now incom...
Страница 115: ... A Configure the RSPAN VLAN SwitchA system view SwitchA vlan 2 SwitchA vlan2 quit Configure GigabitEthernet0 0 1 of Switch A as an observing port and specify the RSPAN VLAN SwitchA observe port 1 interface gigabitethernet 0 0 1 vlan 2 Add GigabitEthernet0 0 1 to the RSPAN VLAN as a trunk interface SwitchA interface gigabitethernet 0 0 1 SwitchA GigabitEthernet0 0 1 port link type trunk SwitchA Gig...
Страница 116: ...gabitethernet 0 0 2 SwitchC GigabitEthernet0 0 2 port link type trunk SwitchC GigabitEthernet0 0 2 port trunk allow pass vlan 2 SwitchC GigabitEthernet0 0 2 quit Configure GE 0 0 1 as a hybrid interface and configure it to allow packets of the RSPAN VLAN to pass SwitchC interface gigabitethernet 0 0 1 SwitchC GigabitEthernet0 0 1 port hybrid untagged vlan 2 SwitchC GigabitEthernet0 0 1 quit Config...
Страница 117: ...bitEthernet 0 0 24 is connected to host 1 GigabitEthernet 0 0 5 is connected to host 2 To monitor incoming traffic on GigabitEthernet 0 0 1 port mirroring is configured on the Switch Configure GigabitEthernet 0 0 1 as a mirrored port and GigabitEthernet 0 0 24 connected to host 1 as an observing port Enable host 1 to receive incoming traffic from GigabitEthernet 0 0 1 At present host 2 needs to re...
Страница 118: ...rnet 0 0 5 Configuration Procedure 1 Check the configurations on the current observing port and mirrored port Run the display port mirroring command to check the configurations on the current observing port and mirrored port Switch display port mirroring Port mirror Mirror port Direction Observe port GigabitEthernet0 0 1 Inbound GigabitEthernet0 0 24 2 Delete the mirrored port Delete the mirrored ...
Страница 119: ...hernet0 0 1 quit 6 Verify the configuration Run the display port mirroring command You can check the configurations on the current observing port and mirrored port Switch display port mirroring Port mirror Mirror port Direction Observe port GigabitEthernet0 0 1 Inbound GigabitEthernet0 0 5 Configuration Files Configuration file of the Switch sysname Switch observe port 1 interface GigabitEthernet0...
Страница 120: ...ection describes the PoE features supported by the S5700 8 3 Configuring PoE Functions This section describes how to configure PoE functions 8 4 Configuration Examples This section provides an example for configuring PoE on the S5700 Quidway S5700 Series Ethernet Switches Configuration Guide Device Management 8 PoE Configuration Issue 01 2011 07 15 Huawei Proprietary and Confidential Copyright Hua...
Страница 121: ...urrent power supply and 250 W constant current power supply A 500 W power supply provides 369 6 W power for the PoE function and a 250 W power supply provides 123 2 W for the PoE function The following S5700 models support PoE l S5700 48TP PWR SI and S5700 52C PWR EI Each switch has two power supply slots Each slot supports a 500 W or 250 W power supply When two PoE power supplies are used determi...
Страница 122: ...tures of PoE interfaces separately for example enable or disable the remote power supply function and set the maximum output power the power supply mode and the power supply priority through commands Pre configuration Tasks Before configuring the PoE functions complete the following task Installing the PoE power supply on the S5700 8 3 2 Configuring the PoE Function Globally Procedure l Optional S...
Страница 123: ...oE power against the total PoE power The S5700 can dynamically allocate power to each interface according to the power consumption of each interface The power consumption of a PD keeps changing when the PD is running The S5700 periodically calculates the total power consumption of all the PDs connected to the device If the total power consumption exceeds the upper threshold of the board the S5700 ...
Страница 124: ... PoE Function on an Interface In an interface view you can enable the PoE function set the maximum output power set the power supply priority and specify the power off time segment Procedure Step 1 Enable the PoE function on an interface 1 Run system view The system view is displayed 2 Run interface interface type interface number The interface view is displayed 3 Run poe enable The PoE function i...
Страница 125: ...s displayed 2 Run time range time name start time to end time days from time1 date1 to time2 date2 The power off time range of a PoE interface is set 3 Run interface interface type interface number The interface view is displayed 4 Run poe power off time range time range name The power off time range takes effect on the interface Step 5 Optional Enable an interface to check compatibility of PDs NO...
Страница 126: ...r supply and PoE board are installed and the PoE function is configured Procedure Step 1 Run the display poe power command to view the status of the PoE power supply Step 2 Run the display poe device command to view information about the devices that support the PoE function Step 3 Run the display poe information command to view the PoE information Step 4 Run the display poe power interface interf...
Страница 127: ... through a wireless network Switch provides power for Switch A Switch B and the AP in automatic mode and is enabled with compatibility detection for PDs Figure 8 1 Networking diagram of PoE configurations Switch SwitchB SwitchA AP GE0 0 1 GE0 0 2 GE0 0 3 Configuration Roadmap The configuration roadmap is as follows 1 Enable PoE on GE 0 0 1 of Switch and configure the maximum power and the power su...
Страница 128: ...enable Switch GigabitEthernet0 0 2 poe power 20000 Switch GigabitEthernet0 0 2 quit 3 Enable PoE on GE 0 0 3 of Switch and set the maximum power consumption of GE 0 0 3 to 2500 mW Switch interface gigabitethernet 0 0 3 Switch GigabitEthernet0 0 3 poe enable Switch GigabitEthernet0 0 3 poe power 2500 Switch GigabitEthernet0 0 3 quit 4 Configure the power supply management of Switch to be in automat...
Страница 129: ...rted by the S5700 This section describes the ALS features supported by the S5700 9 3 Configuring ALS Configuring ALS of the laser of an optical module in the interface view provides security protection and saves energy 9 4 Configuration Examples This section provides a configuration example of ALS Quidway S5700 Series Ethernet Switches Configuration Guide Device Management 9 ALS Configuration Issu...
Страница 130: ... 2 ALS Features Supported by the S5700 This section describes the ALS features supported by the S5700 Applicable Environment of ALS l The switches are connected through fibers When switches are connected through fibers the ALS function can be enabled on interfaces of switches to protect users against laser radiation to eyes as shown in Figure 9 1 Figure 9 1 Connecting switches through fibers Switc...
Страница 131: ...abled on the interface of Switch A and enabled on the interface of Switch B and the interface work in automatic restart mode After the fiber link is recovered the process for interfaces of Switch A and Switch B changing from Down to Up is as follows 1 The optical module laser of Switch A is still working 2 Switch B receives optical signals of Switch A immediately after the fiber link is recovered ...
Страница 132: ...l of the laser ALS pulse width of the laser 9 3 2 Enabling ALS on an Interface The ALS configuration takes effect only after ALS is enabled on an interface Context The constraints on ALS are as follows l Only optical interfaces support ALS Electrical interfaces do not support ALS When optical interfaces transmit services unidirectionally they do not support ALS The hardware must provide support fo...
Страница 133: ...e laser can send pulses immediately Therefore data communication can be recovered rapidly By default the laser works in automatic restart mode after ALS is enabled on all the interfaces Procedure Step 1 Run system view The system view is displayed Step 2 Run interface interface type interface number The interface view is displayed Step 3 Run als restart mode manual The restart mode of the laser is...
Страница 134: ...arted manually Then the laser sends a pulse End 9 3 5 Optional Setting the ALS Pulse Interval and Width of the Laser You can set the proper laser pulse interval and width to ensure energy conservation and emission deduction and timely detection of fiber link recovery Prerequisite The interface is enabled with ALS and works in automatic restart mode Context The ALS pulse width refers to the duratio...
Страница 135: ...he ALS configuration on the specified interface End 9 4 Configuration Examples This section provides a configuration example of ALS 9 4 1 Example for Configuring ALS Through the ALS function a laser can automatically stop sending pulses when a link is faulty and recover pulse transmission after the link is recovered Networking Requirements As shown in Figure 9 3 the LPUs that support ALS are insta...
Страница 136: ...chA interface gigabitethernet 0 0 1 SwitchA GigabitEthernet0 0 1 als enable Set the ALS pulse interval and width of the laser SwitchA GigabitEthernet0 0 1 undo als restart mode manual SwitchA GigabitEthernet0 0 1 als restart pulse interval 200 SwitchA GigabitEthernet0 0 1 als restart pulse width 3 Step 2 Enable ALS on GE 0 0 1 of Switch B configure the laser of the interface to work in automatic r...
Страница 137: ...Interval s Width s Status Status Mode GigabitEthernet0 0 1 Enable Off Auto 200 3 End Configuration Files l Configuration file of Switch A sysname SwitchA interface GigabitEthernet0 0 1 als enable als restart pulse interval 200 als restart pulse width 3 return l Configuration file of Switch B sysname SwitchB interface GigabitEthernet0 0 1 als enable als restart pulse interval 200 als restart pulse ...
Страница 138: ... knowledge in restarting and resetting the S5700 10 2 Restarting the S5700 Immediately This section describes how to restart the S5700 immediately 10 3 Restarting the S5700 at a Fixed Time This section describes how to restart the S5700 at a fixed time Quidway S5700 Series Ethernet Switches Configuration Guide Device Management 10 Restarting and Resetting Issue 01 2011 07 15 Huawei Proprietary and...
Страница 139: ...Ctrl B The advanced BootROM starts the VRP 10 1 2 Process of Starting the BootROM NOTE To check the BootROM startup process you need to connect the Console port of the switch to a terminal by using a serial port cable The BootROM compares the current configuration with the configuration file If they are the same the BootROM asks you whether to reboot the system The message is as follows Info The s...
Страница 140: ...P and then starts the VRP The terminal displays information as follows Decompressing Image file done PPI DEV SysInit OK Hard system init OK Begin to start the system please waiting VOS VFS init OK VOS monitor init OK CFM init advance OK PAT init OK VOS VFS init hind OK VRP_Root begin VRP_InitializeTask begin Init the Device Link OK CFG_PlaneInit begin OK CFM_Init begin OK CLI_CmdInit begin OK VRP_...
Страница 141: ...on can paralyze the network for a while Therefore perform this action with caution Before restarting the S5700 check whether to save the configuration file and whether the file contents are correct For details on saving the configuration file see the Quidway S5700 Series Ethernet Switches Configuration Guide Basic Configuration Procedure Step 1 Press the power button on the S5700 to power off the ...
Страница 142: ...d time is enabled The S5700 does not support the function of restarting the S5700 at a fixed time by default End Quidway S5700 Series Ethernet Switches Configuration Guide Device Management 10 Restarting and Resetting Issue 01 2011 07 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 133 ...