![Huawei S6700 Series Скачать руководство пользователя страница 658](http://html.mh-extra.com/html/huawei/s6700-series/s6700-series_configuration-manual_169517658.webp)
NOTE
In this step, you must specify
vpn-instance
vpn-instance-name
.
Step 3
(Optional) Run the
import-route
{
limt
limt-number
|
protocol
[
process-id
] [
cost
cost
|
route-
policy
route-policy-name
|
tag
tag
|
type
type
]
*
} command to import routes from other routing
protocols.
If another routing protocol is run between an MCE and a site in this VPN, you need to perform
this step.
Step 4
Run the
area
{
area-id
|
area-id-address
} command to create an OSPF area and enter the OSPF
area view.
Step 5
Run the
network
ip-address
wildcard-mask
command to enable OSPF routes on the network
segment where the IP address of the VLANIF interface bound to the VPN instance belongs.
----End
11.5.5 (Optional) Configuring IS-IS Between an MCE and a PE
Context
Do as follows on the MCE.
You need to perform similar configurations on a PE. For details, refer to manuals of
corresponding products.
Procedure
Step 1
Run the
system-view
command to enter the system view.
Step 2
Run the
interface
vlanif
vlan-id
command to enter the view of the VLANIF interface bound to
the VPN instance.
Step 3
Run the
isis enable
[
process-id
] command to enable IS-IS on the VLANIF interface.
By default, IS-IS is disabled on a VLANIF interface.
Step 4
Run the
isis
[
process-id
]
vpn-instance
vpn-instance-name
command to create an IS-IS process
used by a VPN instance and enter the IS-IS view.
Step 5
Run the
network-entity
net
command to configure a NET.
By default, no NET is configured for an IS-IS process.
Step 6
(Optional) Run the
import-route
protocol
[
process-id
] [
cost-type
{
external
|
internal
} |
cost
cost
|
tag
tag
|
route-policy
route-policy-name
| [
level-1
|
level-2
|
level-1-2
] ]
*
command
to import routes from other routing protocols.
If another routing protocol is run between an MCE and a site in this VPN, you need to perform
this step.
----End
11.5.6 (Optional) Configuring BGP Between an MCE and a PE
S6700 Series Ethernet Switches
Configuration Guide - IP Routing
11 MCE Configuration
Issue 01 (2012-03-15)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
639